RIGHTSHIP FOCUS FOR SECTION 4: ISM SYSTEM – 4.27
ISM SYSTEMISM SYSTEM – 4.27fixed fire extinguishing systems
2025-04-17
FOCUS FOR UNSAFE CONDITION AT A MOORING STATION
mooring ropesmooring stationobstacle
2025-01-05
FOCUSED ON CORROSION OF SELF-CONTAINED AIR SUPPORT SYSTEM CYLINDERS IN LIFEBOAT
lifeboatAIR CYLINDER
2024-11-25
FOCUS AN UNSAFE CONDITION ON LIFE RAFT CRADLE
liferaftcradleliferaft
2024-11-19
FOCUS AN UNSAFE CONDITION: DOOR LOCK!
FOCUS FOR AN UNSAFE PORTABLE FAN
PORTABLE FANsafety grillegrille
2024-11-01
FOCUS FOR AN UNSAFE CONDITION! - IMPROPER STORAGE OF TWIST LOCKS ON A LASHING PLATFORM.
firetwistlocktwist locksImproper storagelashing platform.
2024-10-26
FOCUS FOR AN UNSAFE CONDITION IN PASSAGEWAY
passagewaysaltslippery surface
2024-09-28
FOCUS FOR AN UNSAFE CONDITION IN DRY DOCK! - ENSURING CREW SAFETY: ADDRESSING HAZARDS WHILE WORKING AT HEIGHTS ON LIFEBOAT DAVITS
Working at Heights
2024-08-16
FOCUS FOR DESCALE MACHINE
DESCALE MACHINE
2024-06-17
FOCUS FOR UNSAFE CONDITION [ENSURING SAFE SEA PASSAGES: PROPER PREPARATION IN ALL WEATHER CONDITIONS]
Safe Sea Passagesbosun storeAccess hatch
2024-04-21
FOCUS FOR UNSAFE CONDITION [SECURING AND ACCESS CONTROL ON BOARD]
Securing and Access Control
2024-04-21
FOCUS FOR THE WEIGHT TOOLS IN CO2 ROOM
CO2 roomTHE WEIGHT TOOLSCO2 room beam scalescale
2024-04-03
FOCUS FOR SAFETY (PORTABLE LADDER)
portable ladder
2023-11-23
SAFETY COLOR FOR MARKING PHYSICAL HAZARDS
physical hazardsSafety colortripping and fallyellow
2023-03-26
LIFEBOAT REMOTE BRAKE RELEASE LINE
lifeboatLifeboat´s remote brake release linerelease lineremote-control wire
2023-03-21
OBSERVATION#: MOORING WINCHES WERE FOUND WITH MOORING ROPES SECURED ON THE DRUM ENDS.
mooring winchmooring ropesdrum
2023-02-17
OBSERVATION#: INSULATION MATS WERE NOT FULLY PROVIDED AT THE FRONT OF MAIN SWITCHBOARD.
FOUND THAT ONE STUD WAS MISSING FROM THE LINK AND A FEW STUDS WERE NOT SECURED (DIS-LOCATED STUDS).
chainstudlinkkink
2023-01-06
FACTUAL: EXHAUST GAS FROM FF LIFEBOAT ENGINE WHICH WAS SLIGHTLY LEAKING INSIDE THROUGH EXHAUST GAS SILENCER.
free fall lifeboatFFexhaust gas silencerExhaust gasFF LB
2023-01-05
POOP CATWALK GRATING NEAR SUPERSTRUCTURE WAS FOUND AS NOT SECURED. AND SECURING NUTS FOUND MISSING!
FINDING: CARGO HOLD´S BILGE WAS FOUND WITH WATER.
TWO HINGES OF A PILOT DOOR FOUND CRACKED.
hingepilot door
2022-12-01
MISSING SAFETY PINS ON CO2 BOTTLES FOR FIXED FIRE PROTECTION SYSTEM OF EMERGENCY DIESEL GENERATOR.
SAFETY PINemergency diesel generatorCO2 bottlesfixed fire protection system
2022-11-26
DEFECTED/PARTED PROTECTION GRID/HATCH AT CATWALK ON A CONTAINER VESSEL
protection gridhatchcatwalk
2022-11-15
ANTI SPLASH TAPE IS MISSING ON THE AREA OF INLET - OUTLET OF FUEL OIL´S FANGE FOR ME FUEL HIGH PRESSURE PUMP!
anti splash tape
2022-10-25
FIRE LINE CORRODED IN FRONT ACCOMMODATION. TO BE REPAIRED AND TESTED!
THE SIGNS OF EXHAUST GAS LEAK!
M/EA/Eexhaust manifoldM/E exhaust manifold
2022-08-17
BROKEN COUNTERWEIGHT OF ER FAN FLAP
Counterweightfanfan flap
2022-06-27
COUNTER NUTS ON TURN BUCKLES
Counter nutsturn buckles
2022-06-16
REEFER SOCKET CONNECTION BOXES SUPPLY CABLE LINING
reeferReefer socket connection boxesReefer socket connection boxes supply cable lining
2022-05-26
LEAKAGE ON THE FIRE LINE!
leakagefire line
2022-05-16
CRACK ON THE COMPENSATOR
fireCompensatorturbochargerAE
2022-04-30
MISSING COVER FOR LASHING BRIDGES (COULD BE A SERIOUS ACCIDENT FOR CREW AND/OR STEVEDORE)
Lashing bridges
2022-03-27
FOUND RUSTY ROLLERS WHICH ARE HARDLY MOVING THAT CAN CAUSE THE WASTING OF THE ROPES
fairleadsrollers
2022-03-27
AN EXPERIENCE WITH A PILOT LADDER
ISO 799-1(2019)
2022-03-22
DEACTIVATED ECDIS HAZARDS AND ALERTS ON BOTH ECDIS UNITS
ECDISsafety contour
2022-03-22
FOUND AN UNSAFE CONDITION ON SOME DAMAGED GEARBOX BINS.
MISSING SAFETY LASHING WIRE /ROPES TO BE PROVIDED AT STANCHION PIPES
lashinglashing wirelashing ropestanchion
2024-04-03
CORRECTIVE ACTIONS SHALL BE TAKEN FOR ALL SURFACES WITH TEMPERATURES ABOVE 220 °C
FOUND UNSAFE CONDITION FOR A FIRE VALVE
BIG AMOUNT OF SLUDGE PRODUCTION
HANDRAIL AND CHAIN GUARDING
handrailchain guarding
2022-02-13
DISHWASHER MACHINE
DISHWASHER MACHINE
2022-02-13
UNSAFE CONDITION, AN IMPROPER HOSE ARRANGEMENT DURING SLUDGE DISCHARGE OPERATION
Sludge discharge operation
2021-12-13
A HOLE ON THE MAIN FIRE LINE IN VOID SPACE
void spacefire line
2021-10-28
AN UNSAFE CONDITION DUE TO A CORRODED HFO TRANSFER LINE /APPENDIX PIPE
HFO transfer lineappendix pipeleakage
2021-10-24
DB WBT LEVEL SENSOR PIPING-GLAND CORROSION
DB WBT level sensor piping/glandscorrosion
2021-10-23
INOPERABLE FIRE SPRINKLER SYSTEM
Fire sprinkler system
2021-10-22
AN EXPERIENCE WITH INSULATION ON M/E EXHAUST GAS MANIFOLD
insulationsheave housings
2021-10-22
BREAK ROD FOR GALLEY FIRE SYSTEM
galley fire system
2021-10-17
LIFEBOAT - DAMAGED CONTROL WIRE DRUM
lifeboatremote control wirecontrol wire drummain winch drum
2024-02-11
CO2 SYSTEM - CYLINDER VALVE ACTUATOR
CO2 roomCO2 SystemCylinder Valve Actuator
2021-10-14
LOCKING OF THE ENTRANCE ON EMERGENCY EXIT
emergency exitescape routes
2021-10-20
FIRE IN ENGINE SPACES OUR ISOLATION OF FUEL PIPES
Insulation materialself-adhesive tapes
2021-12-18
MAIN ENGINE INSULATION
IMO MSC.1/Circ.1321insulationSensor Connection Pipe
2021-10-16
A 50HZ FREQUENCY RATED MICROWAVE IN CREW MESSROOM
steering gearE/R Oil Tank GaugesMicrowave
2021-10-16
DAMAGED SELF RETRACTABLE LIFELINE
Self Retractable Lifeline
2021-10-16
FIRE DOOR
Class IACS document 2004/Rev.2 2010fire door
2024-07-03
CONDITION OF CO2 CYLINDERS HOSES
DAVIT TYPE LIFEBOAT REMOTE CONTROL WIRE
lifeboatDavit type lifeboatremote control wire
2021-10-20
AN OBSERVED CONDITION FOR CONTAINER SOCKET
container socketscargo operation
2021-10-23