PSC FOCUS: 03104 - CARGO & OTHER HATCHWAYS_CARGO & OTHER HATCHWAYS- WEATHER DECK BALLAST TANK HATCHES FOUND WITH DOGGING ARRANGEMENTS NOT AS REQUIRED. SOME MISSING DOGS. OTHER DOGS WASTED TO THE POINT OF NO BITE UNDER TENSION AND READILY SLIPPING OFF. MUL
CARGO & OTHER HATCHWAYSDOGS
2026-06-04
PSC FOCUS: 18424 - STEAM PIPES, PRESSURE PIPES, WIRES (INSULATION)_STEAM PIPES, PRESSURE PIPES, WIRES (INSULATION)- PIPEWORK RELEASING HOT STEAM AT WALKWAY LEVEL FROM GATE VALVE IN ENGINE ROOM.
STEAM PIPES, PRESSURE PIPES, WIRES (INSULATION)
2026-06-04
PSC FOCUS: 10119 - RUDDER ANGLE INDICATOR_RUDDER ANGLE INDICATOR AT EMERGENCY STEERING POSITION DID NOT RELATE TO THE ACTUAL POSITION OF THE RUDDER. INDICATOR WAS ALSO NOT SECURE.
RUDDER ANGLE INDICATOR
2026-06-04
PSC FOCUS: 18409 - DANGEROUS AREAS - SAFETY CHAINS ON THE WORKING PLATFORM OF STARBOARD SIDE HOSE HANDLING CRANE AND AFT DAVIT INEFFECTIVE TO PREVENT FALL FROM HEIGHT.
Safety chainsDANGEROUS AREAS
2026-05-30
PSC FOCUS: 07106- FIRE DETECTION AND ALARM SYSTEM_FIRE ALARM SYSTEM MANUAL CALL POINT AT BOSUN STORE ENTRANCE DETACHED FROM BULKHEAD AND SECURED WITH CABLE TIES.
manual call pointsFire Detection and alarm systemfire alarm system manual call point
2026-05-29
PSC FOCUS:07105-FIRE DOORS/OPENINGS IN FIRE-RESISTING DIVISIONS_THE SELF-CLOSING DEVICE ON THE FIRE DOOR ON THE AFT OF THE ACCOMMODATION BLOCK 'A'-DECK (ADJACENT TO MASTER'S CABIN) WAS CORRODED AND FULLY DETACHED FROM THE FRAME.
Fire doors/openings in fire-resisting divisions
2026-05-29
PSC FOCUS: 03107-DOORS-EXTERNAL WEATHERTIGHT DOOR TO HOSPITAL FOUND WITH MECHANISM EXCESSIVELY STIFF AND DOGS NOT PROPERLY ENGAGING.
PSC FOCUS: 031-DOORS-BOSUN'S STORE COAMING WASTED IN WAY OF DOGS ON WEATHERTIGHT DOOR. DAYLIGHT SHOWING THROUGH CLOSED DOOR.
PSC FOCUS: 03103-RAILING, GANGWAY, WALKWAY AND MEANS FOR SAFE PASSAGE_WEATHER DECK GANGWAY SHELTER FORWARD STARBOARD SIDE FOUND STOWING ROPES AND UNABLE TO BE USED AS SHELTER.
RAILING, GANGWAY, WALKWAY AND MEANS FOR SAFE PASSAGE
2026-05-29
PSC FOCUS_LIFESAVING SIGNALS_LIFESAVING SIGNALS POSTER WAS NOT DISPLAYED ON THE NAVIGATION BRIDGE AS REQUIRED
LIFESAVING SIGNALSLifesaving signals poster
2026-05-20
PSC FOCUS: VOYAGE OR PASSAGE PLAN
ECDISsocketssafety contourShallow contourVOYAGE OR PASSAGE PLAN
2026-05-20
INJURY DURING MONTAGE OF FO INJECTION PUMP
FO INJECTION PUMP
2026-05-18
PSC FOCUS: FIRE FIGHTING EQUIPMENT AND APPLIANCES_MULTIPLE FIRE HOSES WERE FOUND WITH DUCT TAPE APPLIED TO THE HOSE ENDS. AFTER REMOVAL OF THE TAPE DURING INSPECTION, TWO ENGINE ROOM FIRE HOSES WERE FOUND DEGRADED AND NOT FIT FOR USE.
Fire hosesFIRE FIGHTING EQUIPMENT AND APPLIANCES
2026-05-18
PSC FOCUS: VENTILATION_MULTIPLE CARGO HOLD VENTILATION FANS WERE FOUND NOT OPERATIONAL DURING INSPECTION, INCLUDING: • NO.5 CARGO HOLD FANS: S-40A, S-41A, S-41B, S-42B • NO.6 CARGO HOLD FANS: S-43A, S-43B, S-44A, S-45A, S-45B • NO.7 CARGO HOLD FANS: S-46A
ventilationcargo hold ventilation fan
2026-05-17
PSC FOCUS: VENTILATORS, AIR PIPES, CASINGS_THE NATURAL VENTILATION COAMINGS FOR THE BOSUN STORE AND BOW THRUSTER ROOM WERE FOUND HOLED DUE TO SEVERE CORROSION, WITH OPENINGS APPROXIMATELY 2–3 CM IN DIAMETER.
Ventilators, air pipes, casingsnatural ventilation coamings
2026-05-15
PSC FOCUS: EMERGENCY LIGHTING, BATTERIES AND SWITCHES_THE EMERGENCY LIGHT LOCATED NEAR THE PORT-SIDE LIFERAFT LAUNCHING AREA WAS FOUND NOT OPERATIONAL DURING INSPECTION.
emergency lightEmergency lighting, batteries and switchesliferaft launching area
2026-05-14
PSC FOCUS: EMERGENCY EQUIPMENT FOR 2-WAY COMM_TWO-WAY VHF WRIST STRAP NOT INCLUDED A SUITABLE WEAK LINK TO PREVENT THE BEARER FROM BEING ENSNARED.
two-way portable radiotelephonesocketssuitable weak linkweak linkEmergency equipment for 2-way comm
2026-05-13
PSC FOCUS: DIVISION – DECKS, BULKHEADS AND PENETRATIONS_THE BULKHEAD FIRE PREVENTION STRUCTURAL INTEGRITY DAMAGED BY A CABLE HOLE WITH NO PENETRATION PIECE PROVIDED BETWEEN CABLE TRUNK AND CORRIDOR ON THE E DECK. CONVENTION REFERENCE: SOLAS CHAPTER II-2 –
Division – decks, bulkheads and penetrations
2026-05-12
PSC FOCUS: 15 PPM BILGE ALARM SYSTEM_THE OILY WATER SEPARATOR (OWS) REMAINED IN OPERATION EVEN WHEN SAMPLING WATER WAS NOT ENTERING THE OIL CONTENT METER. NO FLOW ALARM WAS DISPLAYED ON THE CONTROL PANEL DURING TESTING.
OWSoily water separator
2026-05-11
PSC FOCUS: VENTILATORS, AIR PIPES, CASINGS_SEVERAL CARGO HOLD VENTILATOR COVERS WERE FOUND NOT FULLY CLOSABLE, INCLUDING VENTILATORS....
CARGO HOLD VENTILATORVentilators, air pipes, casings
2026-05-11