loading...



PSC/Rightship Filter:
Category: X Tokyo MoU (200)
1 2 3 4 5 6 7 8 9 10 11 All
PSC FOCUS: AUXILIARY ENGINE SYSTEMS_THE NO.1 HFO PURIFIER IS NOT OPERATIONAL
2026-04-11
PSC FOCUS: AUXILIARY ENGINE MONITORING_THE EXHAUST GAS THERMOMETER OF NO.3 GENERATOR ENGINE (G/E) IS MALFUNCTIONING AND NOT PROVIDING ACCURATE READINGS
2026-04-11
PSC FOCUS: EMERGENCY FIRE PUMP SYSTEM_THE DRAIN VALVE HANDLE OF THE EMERGENCY FIRE PUMP IS BROKEN AND NOT OPERABLE
2026-04-09
PSC FOCUS: HATCH COVER OPERATING ARRANGEMENTS_THE HYDRAULIC PIPELINE FOR NO.4 CARGO HOLD HATCH COVER SYSTEM IS RUPTURED, CAUSING HYDRAULIC OIL LEAKAGE.
2026-04-02
PSC FOCUS: HATCH COVER OPERATING ARRANGEMENTS_THE OPERATING CHAIN FOR NO.3 CARGO HOLD HATCH COVER IS HEAVILY CORRODED AND SIGNIFICANTLY THINNED.
2026-04-01
PSC FOCUS: HATCH COVER SECURING ARRANGEMENTS_FOUR CLEATS OF NO.3 CARGO HOLD HATCH COVER ARE DEFORMED AND NOT PROVIDING PROPER SECURING
2026-03-31
PSC FOCUS: PROPULSION MAIN ENGINE_THE ENGINE TELEGRAPH CONTROL AT THE PORT BRIDGE WING IS NOT FUNCTIONAL FOR MAIN ENGINE START AND STOP DURING INSPECTION
2026-03-31
PSC FOCUS: MARITIME LABOUR CERTIFICATE_THE ISSUING DATE OF THE DMLC PART II STATED ON THE MARITIME LABOUR CERTIFICATE IS INCONSISTENT WITH THE DMLC PART II AVAILABLE ON BOARD DURING THE INSPECTION.
2026-03-31
PSC FOCUS: GAUGES AND INDICATORS_THE RPM INDICATOR OF THE MAIN ENGINE ON THE EMERGENCY MANEUVERING PLATFORM IS NOT WORKING / NOT INDICATING CORRECTLY.
2026-03-30
PSC FOCUS: LIFEBOAT_THE SECURING DEVICE FOR HOLDING THE FREE-FALL LIFEBOAT DOOR IN THE OPEN POSITION IS MISSING
2026-03-30
PSC FOCUS: GAUGES, THERHOMETERS, ETC_NUMBER 1 AND 2 GENERATOR ENGINE COOLING WATER PRESSURE GAUGE NOT LEGIBLE.
2026-03-27
PSC FOCUS: MEANS OF CONTROL (OPENING, PUMPS) MACHINERY SPACES_AUXILIARY ENGINE #2 QUICK CLOSING VALVE REPEATEDLY FAILED TO CLOSE DURING TESTING.
2026-03-27
PSC FOCUS: FIRE PUMPS AND ITS PIPES_SECONDARY ACCESS TO EMERGENCY FIRE PUMP LOCKED FROM INSIDE.
2026-03-27
PSC FOCUS: FIRE SAFETY / OIL ACCUMULATION IN ENGINE ROOM
2026-03-27
PSC FOCUS: MANHOLES / FLUSH SCUTTLES
2026-04-01
PSC FOCUS: PILOT LADDERS AND HOIST / PILOT TRANSFER ARRANGEMENTS
2026-04-01
PSC FOCUS: EMBARKATION ARRANGEMENT SURVIVAL CRAFT (DETENTION REASON)
2026-04-01
PSC FOCUS: PROPULSION AND AUXILARY MACHINERY / AUXILARY ENGINE
2026-04-01
PSC FOCUS: FIRE SAFETY / READY AVALIBILITY OF FIRE FIGHTING EQUIPMENT
2026-04-01
PSC FOCUS: LIFE SAVING APPLIANCES / LIFEBUOYS INCL. PROVISION AND DISPOSITION
2026-04-01
PSC FOCUS: STRUCTURAL CONDITIONS – BALLAST, FUEL AND OTHER TANKS (DETENTION REASON)
2026-04-01
PSC FOCUS: WATER/WEATHERTIGHT CONDITIONS – VENTILATORS, AIR PIPES, CASINGS (DETENTION REASON)
2026-02-25
PSC FOCUS: LIFE SAVING APPLIANCES – LIFEBOATS (DETENTION REASON)
2026-02-24
PSC FOCUS: FIRE SAFETY / VENTILATION (DETENTION REASON)
2026-02-23
PSC FOCUS: RADIO COMMUNICATION / OPERATION/MAINTENANCE
2026-02-22
PSC FOCUS: PILOT LADDERS AND HOIST/PILOT TRANSFER ARRANGEMENTS_BOTH PORT AND STARBOARD PILOT LADDERS FOUND WITH SEVERAL LOOSE CHOCKS AT TIME OF INSPECTION.
2026-02-21
PSC FOCUS: REPORTING REQUIREMENTS
2026-02-20
PSC FOCUS: STATEMENT OF COMPLIANCE FOR ANNUAL FUEL OIL CONSUMPTION AND CARBON INTENSITY RATING
2026-02-19
PSC FOCUS: JACKETED HIGH PRESSURE LINES
2026-02-18
PSC FOCUS: SMOKE DETECTOR ACC TO FSS CODE_THE NEAREST SMOKE DETECTOR IS 6.5 METERS AWAY FROM THE BULKHEAD OF MAIN ENGINE STERN TUBE IN ENGINE ROOM, WHICH EXCEEDS THE MAXIMUM 5.5 METERS LIMIT.
2026-02-16
PSC FOCUS: THE TELEGRAPH CONTROL AT PORT BRIDGE WING
2026-02-15
PSC FOCUS: SMOKE DETECTOR ACC TO FSS CODE_THE DISTANCE BETWEEN TWO SMOKE DETECTORS IN THE UPPER AND A DECK ACCOMMODATION CORRIDORS EXCEEDS 11 METERS
2026-01-28
PSC FOCUS: LASHING MATERIAL_AT LEAST FOUR ISO FOUNDATION SOCKETS NEAR SOME BAYS ON THE HATCH COVER ON A CONTAINER VESSEL WERE SERIOUSLY RUSTED.
2025-12-29
PSC FOCUS: STOWAGE OF LIFERAFTS_THE WATERTIGHT INTEGRITY OF THE LIFE RAFT CONTAINER CANNOT BE MAINTAINED DUE TO THE MISSING WATERTIGHT PLUG IN ITS PAINTER HOLE.
2025-12-25
PSC FOCUS: LASHING MATERIAL_SUBSTANTIAL PROTECTIVE CAPS ON THE 440V REEFER PANELS BETWEEN SOME BAYS ON THE WEATHER DECK WERE FOUND MISSING.
2025-12-24
PSC FOCUS: TWO-WAY VHF ON BRIDGE (A WRIST OR NECK STRAP)_NECK STRAP OF THREE TWO-WAY VHF IN WHEELHOUSE NOT CONNECTED WITH WEAK LINK.
2025-12-10
PSC FOCUS: BALLAST WATER RECORD BOOK_THE ITEMS NO 4, IN BWRB NOT RECORDED PROPERLY WHEN UPTAKE BALLAST WATER ON 16-10-2025, 28-10-2025, 12-11-2025.
2025-11-24
PSC FOCUS: BALLAST WATER MANAGEMENT PLAN_BALLAST WATER MANAGEMENT METHODS INCORRECTLY RECORDED IN BWMP.
2025-11-23
PSC FOCUS: LIFEBOAT DAVIT EYE DEFORMATION – CRITICAL SAFETY CONCERN_BOTH LIFEBOATS NOT RELEASED/HOOK-RELEASED AND MANEUVERED INTO THE WATER FOR MORE THAN 6 MONTHS. LAST DRILL CARRIED OUT ON 09-04-2025, BUT UNTIL 04-11-2025 SHIP APPLIED A DISPENSATION LETT
2025-11-21
PSC FOCUS: SECURITY + FIRE AND ABANDON SHIP DRILLS
2025-11-20
PSC FOCUS ON GAUGES, THERMOMETERS ETC_LEVEL GAUGE FOR THE STEERING GEAR RESERVE OIL TANK DEFECTIVE
2025-10-17
PSC FOCUS ON ELECTRICAL EQUIPMENT_ELECTRICAL TERMINAL BOX FOR BOW THRUSTER ROOM FAN SEVERELY CORRODED.
2025-10-16
PSC FOCUS ON FIRE DOOR_FIRE DOORS FOR STEERING GEAR COMPARTMENT AND THE STORE NEXT TO IT FOUND HELD IN THE OPEN POSITION.
2025-10-15
PSC FOCUS ON FLAMMABLE LIQUIDS STORED IN STEERING GEAR ROOM_FLAMMABLE LIQUIDS STORED IN STEERING GEAR ROOM...
2025-10-14
PSC FOCUS ON FIXED CO2 SYSTEM_PERMANENT CONNECTION PROVIDED BETWEEN THE COMPRESSED AIR SYSTEM...
2025-10-13
PSC FOCUS ON FIXED CO2 SYSTEM_SENIOR ENGINEER OFFICER NOT FAMILIAR WITH THE CORRECT EMERGENCY OPERATION OF THE FIXED CO? SYSTEM....
2025-10-10
PSC FOCUS ON WATER MIST SYSTEM_SHIP’S ENGINEER OFFICER NOT FAMILIAR WITH THE EMERGENCY MANUAL RELEASE OF THE WATER MIST SYSTEM.....
2025-10-09
PSC FOCUS ON POSITION VERIFICATION OTHER THAN GPS_POSITION VERIFICATION OF VESSEL (OTHER THAN GPS) ON LAST VOYAGE TO SYDNEY NOT CARRIED OUT IN ACCORDANCE WITH THE PASSAGE PLAN.
2025-10-08
PSC FOCUS: COLLISION PREVENTION WITH FISHING VESSELS IN CHINA’S COASTAL WATERS_CHINA PSC NOW CHECKING TRAINING ON COLLISION PREVENTION GUIDELINES – DON’T GET CAUGHT UNPREPARED!
2025-09-11
PSC FOCUS FOR VENTILATION_DON’T LET YOUR VENTS BETRAY YOU!
2025-08-01
PSC FOCUS FOR VENTILATION_VENTILATION SYSTEM FAILURES – PSC HIGHLIGHTS CRITICAL MAINTENANCE GAPS
2025-08-01
PSC FOCUS FOR CONTINUES SYNOPSIS RECORD (CSR) & AMENDMENT AND INDEX FORMS (FORM 2 & FORM 3)_DURING A RECENT PSC INSPECTION IN NINGBO, CHINA, IT WAS FOUND THAT FORM 2 & 3 FOR CSR WERE MISSING.
2025-07-31
PSC FOCUS FOR 15 PPM ALARM ARRANGEMENT_TAMPERED OR BROKEN OCM SEAL – A DETAINABLE OFFENSE
2025-07-30
PSC FOCUS FOR FIRE-DAMPERS_CONDUCT ROUTINE MANUAL OPERATION OF RARELY-USED DAMPERS TO PREVENT SEIZING. LOG PERIODIC CHECKS IN PMS.
2025-07-29
PSC FOCUS FOR FIRE SAFETY_MISSING SELF-CLOSING CONTROL COCK ON M/E SUMP OIL TANK SOUNDING PIPE
2025-07-28
PSC FOCUS FOR PSC FOCUS FOR COVERS (HATCHWAY-, PORTABLE-, TARPAULINS, ETC.)_ A NON-CLOSING ACCESS HATCH IS A SERIOUS SAFETY CONCERN. FIX IT FAST — OR FACE PSC CONSEQUENCES
2025-07-27
PSC FOCUS FOR EMERGENCY LIGHTING, BATTERIES AND SWITCHES_A MISSING EMERGENCY LIGHT CAN COST YOU MORE THAN JUST A BULB ….
2025-07-26
PSC FOCUS FOR LIGHTS, SHAPES, SOUND-SIGNALS_NAVIGATION SIGNAL LIGHTS/ALARMS IN CONTROL PANEL
2025-07-25
PSC FOCUS FOR ALARM PANEL IN ENGINE CONTROL ROOM_CARGO HOLD BILGES HIGH LEVEL ALARM
2025-07-25
FOCUS FOR EMERGENCY DIESEL GENERATOR_WHEN EVERY SECOND COUNTS, A BROKEN PHONE WON’T HELP
2025-07-23
FOCUS FOR MORSE SIGNAL LIGHT IN MAST_CRACKED MORSE SIGNAL LIGHT DUE TO MAST LOWERING
2025-07-22
PSC FOCUS FOR F.O VISCOSITY CONTROLLER
2025-04-28
PSC FOCUS FOR READINGS OF RUDDER ANGLE
2025-04-27
PSC FOCUS FOR LIFEBOAT - THE FLOAT DRAIN VALVE
2025-04-26
PSC FOCUS FOR PURIFIER ROOM
2025-04-21
PSC FOCUS FOR SIGNAL LIGHT ON MAIN MAST
2025-04-20
PSC FOCUS FOR DAVIT FOR RESCUE BOAT
2025-04-07
PSC FOCUS FOR DAY LIGHT SIGNALLING LAMP
2025-03-28
PSC FOCUS SEWAGE TREATMENT PLAN
2025-03-27
PSC FOCUS LOUVER OF FUNNEL
2025-03-27
PSC FOCUS INCINERATOR
2025-03-21
PSC FOCUS FFLB (FREEFALL LIFEBOAT)
2025-03-20
PSC FOCUS ON FLOOR PLATES IN ENGINE ROOM
2025-03-19
PSC FOCUS RESCUE BOAT
2025-03-18
PSC FOCUS ON SELF-CLOSING DEVICE
2025-03-06
PSC FOCUS ON WATER, PIPES, TANKS
2025-03-03
PSC FOCUS ON WATER, PIPES, TANKS
2025-03-01
PSC FOCUS ON PERMANENT MEANS OF ACCESS
2025-02-28
PSC FOCUS ON EMERGENCY SOURCE OF POWER - EMERGENCY GENERATOR
2025-02-27
PSC FOCUS ON LIFEBOATS
2025-02-26
PSC FOCUS ON EMERGENCY LIGHTING, BATTERIES AND SWITCHES
2025-02-25
PSC FOCUS FOR ENGINE ESCAPE DOOR SEAL
2025-01-14
PSC FOCUS FOR KEEP A RECORD OF KEY EVENTS, ACCIDENTS, AND ISSUES
2025-01-11
PSC FOCUS FOR A CASUALTY EVACUATION DRILLS
2025-01-10
FOCUS FOR IMPORTANT UPDATE ON EMERGENCY ESCAPE TRUNKS REQUIREMENTS IN CHINA AND SINGAPORE
2025-01-09
PSC FOCUS FOR TOTALLY ENCLOSED LIFEBOAT SEATING ARRANGEMENT
2024-12-19
PSC FOCUS ON INDICATOR LIGHTS
2024-11-29
PSC FOCUS ON CARGO SHIP SAFETY RADIO (INCLUDING EXEMPTION)
2024-11-29
PSC FOCUS FOR PUBLIC ADDRESS LOUDSPEAKERS
2024-11-28
FOCUS FOR PSC –WATER/WEATHER TIGHT CONDITIONS _ VENTILATORS, AIR PIPES, CASINGS
2024-11-21
PSC OBSERVATION: OVERFLOW PIPE OBSERVATION GLASS IN F.O. SETTLING TANKS.
2024-10-27
PSC FOCUS - SIGNAL OF MF/HF TRANSMISSION AND RECEPTION
2024-10-16
PSC FOCUS FOR DRY POWDER FIRE EXTINGUISHER
2024-10-16
PSC FOCUS FOR INSULATION MATERIAL
2024-10-16
PSC FOCUS FOR FIRE PUMPS AND ITS PIPES (CODE 07113)
2024-10-15
PSC FOCUS FOR CARGO AND OTHER HATCHWAYS
2024-10-12
PSC FOCUS FOR EMERGENCY DIESEL GENERATOR
2024-10-08
PSC FOCUS FOR VENTILATOR COVER FOR A.H.U (ACCOMMODATION AIR HANDLING UNIT)
2024-09-01
PSC FOCUS FOR EMERGENCY FIRE PUMP – FAIL TO START DURING INSPECTION - DEFECTIVE DELAY TIMER!
2024-09-01
PSC FOCUS FOR FIXED CO2 EXTINGUISHING SYSTEM - INTERPRETATION OF “FSS CODE 2.2.2.2 CONTROLS”
2024-09-01
PSC FOCUS FOR FIRE DAMPERS
2024-09-01
PSC FOCUS FOR ENGINE ROOM FRESHWATER GENERATOR - DEFECTIVE VALVE
2024-08-28
PSC FOCUS FOR ENGINE ROOM (HOUSEKEEPING) - ENGINE ROOM SAFETY ENHANCEMENT: ADDRESSING PASSAGE OBSTRUCTION IDENTIFIED DURING AMSA INSPECTION
2024-08-22
PSC FOCUS FOR OILY WATER SEPERATOR - DEFECTIVE DRAINPIPE
2024-08-22
PSC FOCUS FOR LIFERAFT LAUNCHING INSTRUCTION (TO BE SHIP SPECIFIC)
2024-07-04
PSC FOCUS FOR LIFEBOAT – LIFEBOAT EXTERIOR HULL - RETRO-REFLECTIVE TAPES
2024-07-04
PSC FOCUS FOR THE ACCESS HATCH
2024-07-03
PSC FOCUS FOR EMERGENY ESCAPE TRUNK BY CHINA MSA
2024-06-25
PSC FOCUS FOR MAGNETIC COMPAS-2S
2024-06-27
PSC FOCUS FOR EXTERNAL WATERTIGHT AND WEATHERTIGHT INTEGRITY - CARGO HOLDS ACCESS HATCH COVER
2024-06-07
PSC FOCUS FOR HANDRAIL ON LASHING PLATE - DEFORMED HANDRAIL!
2024-06-03
PSC FOCUS FOR ENTRANCE OF CARGO HOLD - MISSING BUTTERFLY NUT!
2024-06-01
PSC FOCUS FOR FIRE DOOR - THE LOCKER NOT FITTED PROPERLY.
2024-06-01
PSC FOCUS FOR ITU PUBLICATION “LIST V – LIST OF SHIP STATIONS AND MARITIME MOBILE SERVICE IDENTITY ASSIGNMENTS”
2024-05-15
PSC FOCUS FOR LIFEJACKET (MARKER OF REGISTRY PORT NOT MARKED?)
2024-03-04
PSC FOCUS FOR LIGT FOR GMDSS STATION PANEL
2024-02-28
PSC FOCUS FOR POOR INSULATION - AUXILIARY ENGINE FUEL OIL DRAINPIPE…
2024-02-19
PSC FOCUS FOR HOUSEKEEPING IN MAIN ENGINE FUEL OIL PURIFIER
2024-02-19
PSC FOCUS FOR CONTROL PANEL – ALARM FOR HIGH OIL CONTENT IN FEED WATER!
2024-02-19
PSC FOCUS FOR LIFEBOAT ENGINE (DEFECTIVE ELECTRIC CABLE)
2024-02-18
PSC FOCUS FOR HATCH COVER VENTILATION CLOSING DEVICE
2024-02-17
PSC FOCUS FOR HOUSEKEEPING IN EMERGENY GENERATOR ROOM
2024-02-17
PSC FOCUS FOR EMERGENCY LIGHT
2024-02-16
PSC FOCUS FOR LIGHTS AND SIGNALLING EQUIPMENT
2024-02-16
PSC FOCUS FOR SEWAGE TREATMENT PLANT
2024-01-21
PSC FOCUS FOR SELF-CLOSING VALVE
2024-01-20
PSC FOCUS FOR W&R HOURS RECORDING
2024-01-20
PSC FOCUS FOR // TEMPORARILY REPAIRED PIPE
2024-01-17
PSC FOCUS FOR INSULATION // LAGGING // INSULATION // SURFACE TEMPERATURE
2024-01-15
PSC FOCUS FOR HIGH TEMPERATURE COOLER LINE 3-WAY VALVE
2024-01-14
PSC FOCUS FOR // PRESSURE GAUGE
2024-01-14
PSC FOCUS FOR NAVIGATIONAL SIDE LIGHT
2024-01-16
PSC FOCUS FOR CARGO SECURING
2024-01-16
PSC FOCUS FOR MLC // DMLC PART I AND II
2024-01-16
PSC FOCUS FOR MAGNETIC COMPASS
2024-01-16
PSC FOCUS FOR SEA PAINTER OF LIFEBOAT
2024-01-16
PSC FOCUS FOR AUS / MO 32 – LASHING EYE
2024-01-16
PSC FOCUS FOR AUS / MO 32 – STANCHION POCKETS
2024-01-16
PSC FOCUS FOR AUS / MO 32 – HANDRAILS
2024-01-18
PSC FOCUS FOR AUS / MO 32 – SECURING HOOK FOR VERTICAL LADDER
2024-01-18
PSC FOCUS FOR AUS / MO 32 – VERTICAL LADER
2024-01-18
PSC FOCUS FOR AUS / MO 32 – ACCESS COVER, TRANSVARSE WORK PLATFORM
2024-01-18
PSC FOCUS FOR LOAD LINE – HOLD ACCESS RUBBER RETAINING CHANNEL
2024-01-18
PSC FOCUS FOR LOAD LINE – CARGO HOLD VENTILATOR
2024-01-18
PSC FOCUS FOR SECURING WIRE LASHING OF LIFEBOAT
2024-01-18
PSC FOCUS FOR NON-SLIP DECK
2024-01-18
PSC FOCUS FOR LIFEBUOY; NON-KINKING LINE
2024-01-18
PSC FOCUS FOR ANCHOR BITTER END SECURING PIN
2024-01-18
PSC FOCUS FOR FIRE SAFETY (FIRE HOSE)
2024-02-11
PSC FOCUS FOR FIRE SAFETY (SPLASH TAPE)
2024-01-18
PSC FOCUS FOR MEANS OF ESCAPE
2024-01-18
PSC FOCUS FOR FIRE SAFETY (VENTILATION TRUNK DAMPER)
2024-01-18
FOCUS FOR CARGO SHIP SAFETY RADIO CERTIFICATE VS CARGO SHIP SAFETY EQUIPMENT CERTIFICATE
2024-01-18
FOCUS FOR GUARDRAILINGS ON DECK (CUT GUARDRAIL OR SAFETY RAIL)
2023-11-09
PSC FOCUS FOR LIFEBOAT (LIFEBOAT ENGINE INOPERATIVE)
2024-01-18
FOCUS FOR GUARDRAILINGS ON DECK
2024-01-18
PSC FOCUS FOR TWO-WAY VHF ON BDIDGE!
2024-01-18
PSC FOCUS FOR PROPULSION AND AUXILARY MACHINERY - QUICK CLOSING VALVE
2024-01-19
PSC FOCUS FOR FIRE SAFETY/MAINTENANCE OF FIRE PROTECTION SYSTEMS - PAINT ROOM FIXED WATER SPRINKLER SYSTEM
2024-01-19
QUICK-CLOSING VALVE ON ONE OF THE A/ES FUEL INLET PIPE FAILED TO CLOSE REMOTELY.
2024-01-19
PSC FOCUS – WATER/WEATHERTIGHT CONDITION – VENTILATORS, AIR PIPES, CASINGS
2024-01-19
PSC FOCUS – FIRE SAFETY – FIRE DOOR!
2024-01-19
PSC FOCUS – FIRE SAFETY – FIRE PUMP!
2024-01-19
PSC FOCUS – FIRE SAFETY – SEIZED VALVE ON FIRE LINE!
2023-09-17
FOCUS FOR PSC – MARKING OF VENT. MUSHROOM
2024-01-19
FOCUS FOR PSC – IMO SYMBOL!
2024-01-19
FOCUS FOR PSC – EMERGENCY LIGHT!
2024-01-19
FOCUS FOR PSC – LASHING BAR HANGERS!
2024-01-19
FOCUS FOR PSC – FUEL LINES ON EMERGENCY AIR COMPRESSOR!
2024-01-19
FOCUS FOR PSC – SAFETY ON DECK – SECURING EQUIPMENT FROM FALLING!
2024-01-19
FOCUS FOR PSC – GYRO COMPASS REPEATER MOUNTING!
2024-01-19
FOCUS FOR PSC – FIRE SAFETY – VENTILATION
2024-01-19
FOCUS FOR PSC – FUNNEL LOUVRE DAMPERS / FLAPS - FUNNEL FLAPS NOT CLOSING EFFECTIVELY!
2024-01-19
FOCUS FOR PSC – FIRE SAFETY / FIXED FIRE EXTINGUISHING INSTALLATION
2024-01-22
FOCUS FOR PSC – PRESSURE GAUGE
2024-01-22
FOCUS FOR PSC – PROPULSION AND AUXILIARY MACHINERY - PROPULSION MAIN ENGINE.
2024-01-22
FOCUS FOR PSC – PRECAUTIONS REQUIRED FOR LAGGING AND INSULATIONS.
2024-01-22
SOME POSSIBLE PSC DEFICIENCIES LIST
2024-01-22
NATURE OF DEFICIENCY: SOPEP HOSE EQUIPMENT FOR AIR PUMP IS MISSING.
2024-01-22
NATURE OF DEFICIENCY: 440V PANEL BOARD AT ENGINE ROOM WITHOUT RUBBER MATTING.
2024-01-22
MLC TITLE 3 ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING.
2024-01-22
AMSA, DEFICIENCY: TOE BOARDS
2024-01-22
AMSA, DEFICIENCY: LIGHT FITTINGS IN-WAY-OF ACCESS LADDER
2024-01-22
AMSA, DEFICIENCY: ACCESS FLAPS TO WALKWAYS
2024-01-24
AMSA, DEFICIENCY: WALKWAY GRATINGS ON CONTAINER LASHING BRIDGES
2024-01-24
SOME AMSA INSPECTION (TOKYO MOU) FINDINGS!
2024-01-29
PILOT LADDER´S SIDE ROPE BROKE DURING PILOT BOARDING!
2024-01-29
PSC DEFICIENCY - ON MAIN SWITCHBOARD 440 V ELECTRICAL INSULATION AROUND 0.1MOHM WAS OBSERVED
2024-01-29
PSC / MPA SINGAPORE / DEFICIENCY: WINCHES MOTOR GUARD RAILS FOUND CORRODED WASTED SUBSTANTIALLY.
2024-02-05
PSC / MPA SINGAPORE / DEFICIENCY: LSA - LIFEBOAT BOLLARDS FOUND WASTED/RUSTED SUBSTANTIALLY.
2024-02-05
MSA CHINA´S ENQUIRY ABOUT SEWAGE AND STORAGE!
2024-02-11
PSC EXPERIENCE IN AUS (AMSA) ELECTRICAL CIRCUIT (JUMPER)
2024-02-11
PSC EXPERIENCE IN AUS (AMSA)
2024-02-11
PSC EXPERIENCE IN BUSAN
2024-02-11
PSC PHILIPPINE COAST GUARD
2024-02-11
CHINA MSA ANTI POLLUTION ONLINE INSPECTION
2024-02-11
PSC EXPERIENCE IN ASIA PACIFIC REGION
2023-09-10
PSC EXPERIENCE IN ASIA REGARDING ER OIL TANK GAUGES
2024-01-18
PSC EXPERIENCE IN CHINA
2024-01-18
PSC EXPPERIENCE IN HONG KONG
2024-01-18
1 2 3 4 5 6 7 8 9 10 11 All
Choose Location
Subscribe to AlertClub
This webpage is for the purpose to share experience and knowledge. Please always consider your case based on your encountered facts and conditions together with your related internal and/or external/international regulation.
Success Your changes has been saved