PSC FOCUS: PREVENTION OF OCCUPATIONAL INJURIES AND DISEASES_HEAVY BOXES, SPARE PARTS, AND MATERIALS WERE FOUND IMPROPERLY SECURED OR UNSECURED IN WEATHER PASSAGES AND THE STEERING GEAR ROOM.
2026-04-20
PSC FOCUS: CREW TRAINING AND FAMILIARIZATION_JUNIOR OFFICERS DEMONSTRATED INSUFFICIENT KNOWLEDGE OF THE BALLAST WATER MANAGEMENT PLAN (BWMP).
2026-04-20
PSC FOCUS: GAUGES AND THERMOMETERS_ONE THERMOMETER ON AIR COMPRESSOR NO.1 AND ONE PRESSURE GAUGE ON AIR COMPRESSOR NO.2 WERE FOUND BROKEN OR NOT OPERATIONAL.
2026-04-19
PSC FOCUS: AUXILIARY ENGINE SYSTEMS_AUXILIARY ENGINES NO.1, NO.2, AND NO.4 HAVE ACTIVE OIL LEAKAGES OBSERVED DURING INSPECTION.
2026-04-17
FOCUS: CO? SYSTEM – VERIFY PILOT CYLINDER CONNECTIONS AFTER DRY DOCK
2026-04-16
PSC FOCUS: AUXILIARY ENGINE SYSTEMS_THE NO.1 HFO PURIFIER IS NOT OPERATIONAL
2026-04-11
PSC FOCUS: AUXILIARY ENGINE MONITORING_THE EXHAUST GAS THERMOMETER OF NO.3 GENERATOR ENGINE (G/E) IS MALFUNCTIONING AND NOT PROVIDING ACCURATE READINGS
2026-04-11
PSC FOCUS: GAUGES AND INDICATORS_THE RPM INDICATOR OF THE MAIN ENGINE ON THE EMERGENCY MANEUVERING PLATFORM IS NOT WORKING / NOT INDICATING CORRECTLY.
2026-03-30
PSC FOCUS: REMOTE MEANS OF CONTROL (OPNENING, PUMPS, VENTILATON, ETC) MACHINERY SPACES_DURING TESTING, LOCAL QUICK-CLOSING VALVES OF DG NO.1 AND DG NO.3 SHOWED HYDRAULIC LEAKAGES.
2026-03-28
PSC FOCUS: CODE 02150_STEERING GEAR_HYDRAULIC PIPELINE CONNECTION SHOWS SEVERAL POINT OF SMALL LEAKAGES. THE SYSTEM IS FULLY OPERATIVE.
2026-03-27
INCIDENT FOCUS: A FIRE IN ENGINE ROOM_SMALL COMPONENT, SERIOUS CONSEQUENCE: FUEL PUMP SHOCK ABSORBER GASKET FAILURE!
2026-03-24
PSC FOCUS: GAUGES, THERHOMETERS, ETC_NUMBER 1 AND 2 GENERATOR ENGINE COOLING WATER PRESSURE GAUGE NOT LEGIBLE.
2026-03-27
PSC FOCUS: MEANS OF CONTROL (OPENING, PUMPS) MACHINERY SPACES_AUXILIARY ENGINE #2 QUICK CLOSING VALVE REPEATEDLY FAILED TO CLOSE DURING TESTING.
2026-03-27
PSC FOCUS: FIRE DETECTION AND ALARM SYSTEM
2026-03-27
PSC FOCUS: FIRE SAFETY / OIL ACCUMULATION IN ENGINE ROOM
2026-03-27
PSC FOCUS: PROPULSION AND AUXILARY MACHINERY / AUXILARY ENGINE
2026-04-01
PSC FOCUS: STATEMENT OF COMPLIANCE FOR ANNUAL FUEL OIL CONSUMPTION AND CARBON INTENSITY RATING
2026-02-19
PSC FOCUS: JACKETED HIGH PRESSURE LINES
2026-02-18
PSC FOCUS: SMOKE DETECTOR ACC TO FSS CODE_THE NEAREST SMOKE DETECTOR IS 6.5 METERS AWAY FROM THE BULKHEAD OF MAIN ENGINE STERN TUBE IN ENGINE ROOM, WHICH EXCEEDS THE MAXIMUM 5.5 METERS LIMIT.
2026-02-16
NEW STANDARD FOR ENCLOSED SPACE SAFETY
2026-02-13
FOCUS ON INSULATION AND LAGGING – IMPROPER INSTALLATION RISKS
2026-02-04
SPLASH GUARDING [CONNECTIONS IN THE FUIL OIL AND LUBRICATING OIL SYSTEM]
2026-02-02
FOCUS ON MAXIMUM PERMISSIBLE SEWAGE DISCHARGE RATE (APPLICABLE ONLY TO VESSELS FITTED WITH SEWAGE HOLDING TANKS)
2026-01-31
RIGHTSHIP FOCUS: FOR SECTION 13-13.8: MACHINERY SPACE_ENGINE ROOM BILGE ALARM WAS BEING TESTED WEEKLY BUT NOT ONCE EVERY WATCH OR PART OF PRE UMS CHECKS
2026-01-04
RIGHTSHIP FOCUS: FOR SECTION 13: MACHINERY SPACE. 13.11_THERE WERE NO RECORDS AVAILABLE FOR ANY TRAINING CARRIED OUT BY SHIP’S OFFICERS ON CLASS APPROVED PMS INSTALLED ONBOARD
2026-01-02
RIGHTSHIP FOCUS: FOR SECTION 13 - 13.7 MACHINERY SPACE_PRIMING PUMP FOR EMERGENCY FIRE PUMP COULD BE ENGAGED ON ITS OWN TO BUILT UP THE PRESSURE BUT WAS BEING ENGAGED MANUALLY.
2026-01-01
PSC FOCUS: BALLAST WATER MANAGEMENT PLAN_BALLAST WATER MANAGEMENT METHODS INCORRECTLY RECORDED IN BWMP.
2025-11-23
PSC FOCUS: BOILER ROOM VENTILATION DUCT
2025-11-15
FOCUS FOR AN UNSAFE CONDITION IN PASSAGEWAY_ENSURING SAFE PASSAGE: ADDRESSING FIRE LINE LEAKAGE AND PREVENTIVE MEASURES
2025-11-09
PSC FOCUS ON GAUGES, THERMOMETERS ETC_LEVEL GAUGE FOR THE STEERING GEAR RESERVE OIL TANK DEFECTIVE
2025-10-17
PSC FOCUS ON FIRE DOOR_FIRE DOORS FOR STEERING GEAR COMPARTMENT AND THE STORE NEXT TO IT FOUND HELD IN THE OPEN POSITION.
2025-10-15
PSC FOCUS ON FLAMMABLE LIQUIDS STORED IN STEERING GEAR ROOM_FLAMMABLE LIQUIDS STORED IN STEERING GEAR ROOM...
2025-10-14
PSC FOCUS ON FIXED CO2 SYSTEM_PERMANENT CONNECTION PROVIDED BETWEEN THE COMPRESSED AIR SYSTEM...
2025-10-13
PSC FOCUS ON FIXED CO2 SYSTEM_SENIOR ENGINEER OFFICER NOT FAMILIAR WITH THE CORRECT EMERGENCY OPERATION OF THE FIXED CO? SYSTEM....
2025-10-10
PSC FOCUS ON WATER MIST SYSTEM_SHIP’S ENGINEER OFFICER NOT FAMILIAR WITH THE EMERGENCY MANUAL RELEASE OF THE WATER MIST SYSTEM.....
2025-10-09
PSC FOCUS ON FIRE DOORS/OPENINGS IN FIRE-RESISTING DIVISIONS_EMERGENCY EXIT IN ENGINE ROOM AT LOWEST PLATFORM AFT IS NOT CLOSING BY ITSELF/PROPERLY
2025-10-01
PSC FOCUS ON CONCENTRATED INSPECTION CAMPAIGN ON BALLAST WATER MANAGEMENT_MOST COMMON DEFICIENCIES LEADING TO DETENTION
2025-09-29
FOCUS ON “WHY ENCLOSED SPACE INCIDENT STILL HAPPEN”_ROOT CAUSES BEHIND ENCLOSED SPACE TRAGEDIES
2025-09-10
PSC FOCUS FOR UMS SHIP_AUTOMATIC PRINTING = AUTOMATIC COMPLIANCE, LET THE PRINTER WORK FOR YOU
2025-09-08
PSC FOCUS FOR GUARDS - FENCING AROUND DANGEROUS MACHINERY PARTS_MISSING EQUIPMENT
2025-09-05
PSC FOCUS FOR OPERATION OF MACHINERY_LACK OF FAMILIRIZATION
2025-09-03
PSC FOCUS FOR GAUGES, THERMOMETERS, ETC_GAUGE RAGE – PSC’S FAVORITE CATCH!
2025-09-02
PSC FOCUS FOR PROPULSION MAIN ENGINE_COOLING WATER LEAKS UNDER PSC SPOTLIGHT
2025-09-01
PSC FOCUS FOR FIRE DETECTION_SMOKE DETECTION IS YOUR FIRST LINE OF DEFENSE AGAINST FIRE
2025-08-28
PSC FOCUS FOR MEANS OF COMMUNICATION BETWEEN SAFETY CENTRE AND OTHER CONTROL STATIONS_“HELLO? …HELLO? …PSC IS CALLING!”
2025-08-27
PSC FOCUS FOR COVERS (HATCHWAY-, PORTABLE-, TARPAULINS, ETC.)_WATERTIGHT INTEGRITY COMPROMISED
2025-08-26
PSC FOCUS FOR COVERS (HATCHWAY-, PORTABLE-, TARPAULINS, ETC.)_HATCH & DUCT KEEL CONDITION!
2025-08-25
PSC FOCUS FOR ORB ENTRANCE_ ALWAYS RECORD BUNKERING OPERATIONS IN ORB PART I WITHOUT DELAY TO AVOID PSC DEFICIENCIES
2025-08-20
PSC FOCUS FOR 15 PPM ALARM ARRANGEMENT_TAMPERED OR BROKEN OCM SEAL – A DETAINABLE OFFENSE
2025-07-30
PSC FOCUS FOR FIRE-DAMPERS_CONDUCT ROUTINE MANUAL OPERATION OF RARELY-USED DAMPERS TO PREVENT SEIZING. LOG PERIODIC CHECKS IN PMS.
2025-07-29
PSC FOCUS FOR FIRE SAFETY_MISSING SELF-CLOSING CONTROL COCK ON M/E SUMP OIL TANK SOUNDING PIPE
2025-07-28
PSC FOCUS FOR ALARM PANEL IN ENGINE CONTROL ROOM_CARGO HOLD BILGES HIGH LEVEL ALARM
2025-07-25
FOCUS FOR EMERGENCY DIESEL GENERATOR_WHEN EVERY SECOND COUNTS, A BROKEN PHONE WON’T HELP
2025-07-23
RIGHTSHIP FOCUS SECTION 2: CERTIFICATION AND PERSONAL MANAGEMENT – 2.5_“I WORKED… JUST DIDN’T WRITE IT DOWN – NOT GOOD ENOUGH FOR RIGHTSHIP!”
2025-07-19
RIGHTSHIP FOCUS FOR SECTION 5: POLLUTION PREVENTION AND CONTROL – 5.25_SOUNDING WITHOUT SOUND
2025-07-16
RIGHTSHIP FOCUS FOR SECTION 5: POLLUTION PREVENTION AND CONTROL – 5.13_CHIEF ENGINEER & MASTER HAVE EYES ON THIS VALVE
2025-07-15
USCG FOCUS FOR OWS - MARPOL ANNEX 1/14.2
2025-06-27
RIGHTSHIP FOCUS FOR SECTION 13: MACHINERY SPACE – 13.19
2025-06-16
RIGHTSHIP FOCUS FOR SECTION 13: MACHINERY SPACE – 13.13
2025-06-13
FOCUS FOR RISK OF CRUSHING BY HEAVY MATERIALS
2025-06-05
FOCUS FOR OWS – 15 PPM BILGE ALARM MONITOR
2025-06-03
RIGHTSHIP FOCUS FOR SECTION 4: ISM SYSTEM – 4.17 (CHECK YOUR WORKSHOP TODAY — ARE YOUR HOSE CLAMPS SAFE AND COMPLIANT?)
2025-06-01
USCG FOCUS FOR LEAKING BOILER LINE
2025-05-13
FOCUS FOR: SAY GOODBYE TO BUCKETS & CANS – FIX IT RIGHT!
2025-05-07
PSC FOCUS FOR F.O VISCOSITY CONTROLLER
2025-04-28
PSC FOCUS FOR READINGS OF RUDDER ANGLE
2025-04-27
PSC FOCUS FOR PURIFIER ROOM
2025-04-21
RIGHTSHIP FOCUS FOR SECTION 13: MACHINERY SPACE – 13.25
2025-04-14
FOCUS FOR AN INJURY ON LATTE MACHINE (DURING WORK WITH ROTATING MACHINERY)
2025-04-12
PSC FOCUS SEWAGE TREATMENT PLAN
2025-03-27
PSC FOCUS INCINERATOR
2025-03-21
PSC FOCUS ON FLOOR PLATES IN ENGINE ROOM
2025-03-19
PSC FOCUS ON SELF-CLOSING DEVICE
2025-03-06
FOCUS ON UNSAFE ACT - WHAT’S MISSING HERE?
2025-02-14
FOCUS FOR AN INCIDENT ….DURING A/E NO. 1 PIT STOP OVERHAUL….
2025-01-29
PSC FOCUS FOR CO2 CYLINDER – PILOT LOOP (HOSE)
2025-01-14
PSC FOCUS FOR ENGINE ESCAPE DOOR SEAL
2025-01-14
FOCUS FOR CLEAN MACHINERY SPACES
2025-01-12
PSC FOCUS FOR KEEP A RECORD OF KEY EVENTS, ACCIDENTS, AND ISSUES
2025-01-11
PSC FOCUS FOR A CASUALTY EVACUATION DRILLS
2025-01-10
FOCUS FOR IMPORTANT UPDATE ON EMERGENCY ESCAPE TRUNKS REQUIREMENTS IN CHINA AND SINGAPORE
2025-01-09
FOCUS FOR AN ACCIDENT
2024-12-08
FOCUS FOR AN INCIDENT_LO PUMP ELECTRIC MOTOR ISSUE (FAILURE OF PUMP NUMBER 1 & 2)
2024-11-28
PSC FOCUS – QUICK CLOSING VALVE
PSC OBSERVATION: FLEXIBLE HOSE IN CO2 ROOM
CHALLENGING SET-UP: HOW WOULD YOU TEST THIS FIRE DETECTOR (SMOKE)?
2024-11-14
FOCUS FOR AN INCIDENT - THE ISSUE WITH MAIN STARTING VALVE
2024-11-12
PSC OBSERVATION: FLOOR PLATES IN ENGINE ROOM
2024-11-08
PSC OBSERVATION: BALLAST WATER TREATMENT SYSTEM
2024-11-07
PSC OBSERVATION: CERTIFICATE OF RECOGNATION
2024-11-02
FOCUS FOR AN UNSAFE PORTABLE FAN
2024-11-01
PSC OBSERVATION: MISSING TECHNICAL FILE
2024-10-30
PSC OBSERVATION: WORK AND REST HOUR
2024-10-30
PSC OBSERVATION: OVERFLOW PIPE OBSERVATION GLASS IN F.O. SETTLING TANKS.
2024-10-27
PSC FOCUS FOR INSULATION MATERIAL
2024-10-16
FOCUS FOR A SAFETY BREACH: WATERTIGHT DOOR IMPROPERLY SECURED
2024-10-10
FOCUS FOR LATHE MACHINE FOOT EMERGENCY STOP
2024-10-09
FOCUS FOR AN ACCIDENT - UNEXPECTED BACK PRESSURE DURING AIR BLOWING OF CO2 PIPE
2024-10-04
FOCUS FOR AN UNSAFE CONDITION IN PASSAGEWAY
2024-09-28
FOCUS FOR STEERING GEAR OIL STORAGE TANK
2024-09-23
PSC FOCUS FOR SWL MARKING
2024-09-03
PSC FOCUS FOR SAFETY - LATHE MACHINE
2024-09-03
PSC FOCUS FOR FIRE / SPARK PROOF SAFETY CURTAIN
2024-09-02
PSC FOCUS FOR THE BOTTOM PLATFORM GRATINGS IN THE ENGINE ROOM
2024-09-02
PSC FOCUS FOR ENGINE ROOM FRESHWATER GENERATOR - DEFECTIVE VALVE
2024-08-28
PSC FOCUS FOR ENGINE ROOM (HOUSEKEEPING) - ENGINE ROOM SAFETY ENHANCEMENT: ADDRESSING PASSAGE OBSTRUCTION IDENTIFIED DURING AMSA INSPECTION
2024-08-22
PSC FOCUS FOR OILY WATER SEPERATOR - DEFECTIVE DRAINPIPE
2024-08-22
FOCUS FOR FIRE DETECTION DISPLAY PANEL
2024-08-13
FOCUS FOR OIL WATER SPERATOR
2024-07-18
PSC FOCUS FOR EMERGENY ESCAPE TRUNK BY CHINA MSA
2024-06-25
FOCUS FOR STEERING GEAR – A FEW POINTS…
2024-05-27
PSC FOCUS FOR EMERGENCY SOURCE OF POWER – EMERGENCY GENERATOR
2024-05-25
FOCUS FOR EMERGENCY GENERATOR
2024-05-24
FOCUS FOR EMERGENCY FIRE PUMP
2024-05-23
FOCUS FOR AN ACCIDENT-FINGER SQUEEZED!
2024-05-16
PSC FOCUS FOR AUXILIARY ENGINE
2024-04-26
PSC FOCUS FOR PROPULSION MAIN ENGINE
2024-04-26
PSC FOCUS FOR FUEL SAMPLING POINTS
2024-04-17
PSC FOCUS FOR FW GENERATOR EJECTOR PUMP DISCHARGE VALVE
2024-04-12
FOCUS FOR THE WEIGHT TOOLS IN CO2 ROOM
2024-04-03
PSC FOCUS FOR INTERNATIONAL SEWAGE POLLUTION PREVENTIVE CERTIFICATE
2024-04-01
PSC FOCUS FOR GAUGES, THERMOMETERS, ETC.
2024-03-29
PSC FOCUS FOR HOUSKEEPING ON BEDPLATE/FOUNDATIO BOLD AREA
2024-04-03
PSC FOCUS FOR FAILURE TO REPORT MALFUNCTIONUNG OF EQUIPMENT & MACHINERY…
2024-02-19
PSC FOCUS FOR POOR INSULATION - AUXILIARY ENGINE FUEL OIL DRAINPIPE…
2024-02-19
PSC FOCUS FOR HOUSEKEEPING IN MAIN ENGINE FUEL OIL PURIFIER
2024-02-19
PSC FOCUS FOR CONTROL PANEL – ALARM FOR HIGH OIL CONTENT IN FEED WATER!
2024-02-19
PSC FOCUS FOR IMO GRAPHICAL SYMBOL - GRAPHICAL SYMBOLS FOR FIRE-PROTECTION APPLIANCES
PSC FOCUS FOR HOUSKEEPING IN ENGINE ROOM – POOR INSULATION
PSC FOCUS FOR HOUSKEEPING IN ENGINE ROOM - LUB. OIL COOLER FOR A/E
PSC FOCUS FOR SEWAGE TREATMENT PLANT
2024-01-21
PSC FOCUS FOR SELF-CLOSING VALVE
2024-01-20
FOCUS FOR PSC // SAMPLING POINT CONNECTION TO OIL WATER SEPARATOR
2024-01-18
PSC FOCUS FOR // TEMPORARILY REPAIRED PIPE
2024-01-17
PSC FOCUS FOR INSULATION // LAGGING // INSULATION // SURFACE TEMPERATURE
2024-01-15
PSC FOCUS FOR HIGH TEMPERATURE COOLER LINE 3-WAY VALVE
2024-01-14
PSC FOCUS FOR // PRESSURE GAUGE
2024-01-14
FOCUS FOR CROWNS – CASING - LAMELLAS
2024-01-11
PSC FOCUS FOR NON-SLIP DECK
2024-01-18
PSC FOCUS FOR ELECTRICAL INSULATION!
2023-12-03
PSC FOCUS FOR SEWAGE TREATMENT HOSES (B/W CHAMBERS)
2023-11-23
FOCUS FOR SAFETY (PORTABLE LADDER)
2023-11-23
PSC FOCUS FOR FIRE SAFETY (FIRE HOSE)
2024-02-11
PSC FOCUS FOR FIRE SAFETY (SPLASH TAPE)
2024-01-18
PSC FOCUS FOR MEANS OF ESCAPE
2024-01-18
PSC FOCUS FOR PROPULSION AND AUXILARY MACHINERY - QUICK CLOSING VALVE
2024-01-19
QUICK-CLOSING VALVE ON ONE OF THE A/ES FUEL INLET PIPE FAILED TO CLOSE REMOTELY.
2024-01-19
FOCUS FOR FUEL SAMPLING POINTS TO BE MARKED AND LABELED AS PER MEPC.1/CIRC.864/REV.1. MEPC.1- CIRC.882
2023-09-27
FOCUS FOR FIXED CO2 SYSTEM – TRANSPORTATION PIN!
2023-09-19
PSC FOCUS – WATER/WEATHERTIGHT CONDITION – VENTILATORS, AIR PIPES, CASINGS
2024-01-19
FOCUS FOR PSC – IMO SYMBOL!
2024-01-19
FOCUS FOR PSC – EMERGENCY LIGHT!
2024-01-19
FOCUS FOR PSC – FUEL FILTER UNIT OF EMERGENCY GENERATOR - FOUND LEAKAGE!
2024-01-22
FOCUS FOR PSC – FIRE SAFETY / FIXED FIRE EXTINGUISHING INSTALLATION
2024-01-22
FOCUS FOR PSC – POLUTION PREVENTION – MARPOL ANNEX IV – SEWAGE TREATMENT PLANT
2024-01-22
FAILURE OF ME LO PUMP!
2023-08-19
FOCUS FOR PSC – PRESSURE GAUGE
2024-01-22
FOCUS FOR PSC – PROPULSION AND AUXILIARY MACHINERY - PROPULSION MAIN ENGINE.
2024-01-22
FOCUS FOR PSC – PRECAUTIONS REQUIRED FOR LAGGING AND INSULATIONS.
2024-01-22
BROKEN NON-RETURN VALVE AND PIPE FROM ONE OF THE M.E. UNITS´ EXHAUST GAS VALVE
2023-07-10
SOME POSSIBLE PSC DEFICIENCIES LIST
2024-01-22
THE ALTERNATOR OF AUXILARY ENGINE JUNCTION BOX
2023-06-23
NATURE OF DEFICIENCY: 440V PANEL BOARD AT ENGINE ROOM WITHOUT RUBBER MATTING.
2024-01-22
USCG, PSCO OBSERVED MODERATE POOLING OF FUEL OIL AROUND MULTIPLE FUEL PUMPS FOR THE M/E.
2024-01-22
LUB. OIL LEAK FROM ONE OF AUX ENGINE LUB. OIL COOLER.
2024-01-24
E/R BLOWER FAN ROOM
2024-01-24
INSULATION MATERIAL ON CO2 ROOM BULKHEAD
2024-01-24
MAIN COOLING SEA WATER PUMP LEAKING FROM SHAFT PACKING
2024-01-24
LEAKAGE WAS OBSERVED FROM ONE OF ME CYLINDER AFT FO INJECTION VALVE
2023-03-01
OBSERVATION#: INSULATION MATS WERE NOT FULLY PROVIDED AT THE FRONT OF MAIN SWITCHBOARD.
2023-02-17
DEFICIENCY#: L.O. TANK OUTLET PIPE LOCATED AT ENGINE ROOM BOTTOM FLOOR WAS FOUND LEAKING OIL FROM THE VALVE.
2024-01-29
DEFICIENCY#: ENGINE ROOM TANK-TOP WAS FOUND WITH OIL LEAKAGE ACCUMULATED EXCESSIVELY.
2024-01-29
DEFECTIVE O-RING. LO LEAKAGE FROM SG LO STORAGE TANK SIDE GLASS WAS FOUND DURING USCG INSPECTION.
2024-01-29
SOME AMSA INSPECTION (TOKYO MOU) FINDINGS!
2024-01-29
ELECTRICAL INSTALLATIONS IN GENERAL/BATTERY ROOM ILLUMINATING LIGHT PROTECTIVE COVER (EXPLOSION PROOF TYPE) WAS FOUND BROKEN.
2024-01-29
STEERING GEAR AND 28 SECONDS RULE!
2024-01-29
VERTICAL ESCAPE EQUIPMENT AND EMERGENCY ESCAPE RESCUE LINE IN EMERGENCY ESCAPE TRUNK
2023-01-04
MISSING SAFETY PINS ON CO2 BOTTLES FOR FIXED FIRE PROTECTION SYSTEM OF EMERGENCY DIESEL GENERATOR.
2022-11-26
REPLACING OF THE FOAM APPLICATOR FROM EMERGENCY DIESEL GENERATOR!
2022-11-26
OBSERVATION REGARDING THE POSITION OF A FIRE EXTINGUISHER.
2022-11-22
PSC DEFICIENCY - ON MAIN SWITCHBOARD 440 V ELECTRICAL INSULATION AROUND 0.1MOHM WAS OBSERVED
2024-01-29
ANTI SPLASH TAPE IS MISSING ON THE AREA OF INLET - OUTLET OF FUEL OIL´S FANGE FOR ME FUEL HIGH PRESSURE PUMP!
2022-10-25
ER PIPING SHOULD BE FREE OF ANY CEMENT BOXES, DOUBLERS, SOFT PATCHES, ETC
2023-09-12
PSC DEFICIENCY / FOUND INSULATION WETTED WITH OIL.
2024-02-02
PSC DEFICIENCY / LEAKAGE FOUND ON AUXILIARY GENERATOR DURING PSC.
2024-02-02
PSC DEFICIENCY / LEAKAGE FOUND ON MAIN ENGINE DURING PSC.
2024-02-02
PSC DEFICIENCY / LB´S ENGINE EXHAUST PIPE FOUND WITH A STRANGE SOUND, POSSIBLE DUE TO THE CORROSION.
2024-02-05
ENGINE ROOM – PIPELINES IN GENERAL WERE FOUND CORRODED. FRESH WATER GEN – ME JACKET WATER LINE INLET FLANGE AS RECORDED.
2024-02-05
ENGINE ROOM - LT COOLER 2 - SW INLET FLANGE FOUND AS HEAVILY CORRODED
2024-02-05
THE SIGNS OF EXHAUST GAS LEAK!
2022-08-17
ACCIDENT BY CRUSHING
2022-08-16
PROPER STORAGE OF WASTE OIL IN DRUM
2024-02-05
AN ACCIDENT DURING DISMANTLE OF AIR COOLER´S COVER ON ONE OF AE
2022-08-09
BROKEN COUNTERWEIGHT OF ER FAN FLAP
2022-06-27
ONE M.E UNIT HIGH PRESSURE PIPE HAS THE LEAKAGE
2022-06-20
SAFETY HARNESS
2022-06-17
A PSC FINDING (MINOR) ABOUT THE FIRE HOSE NEAR WORKSHOP (MOVABLE METAL FRAME) WAS OBSTRUCTED BY METAL PIPE
2024-02-05
DEFICIENCY BY PARIS MOU: FFE NOTED OBSTRUCTED BY STORES AND OTHER EQUIPMENT AT VARIOUS LOCATION.
2024-02-05
CRACK ON THE COMPENSATOR
2022-04-30
LOW SULPHUR FUELS / TANK SENSOR TUBE GLAND TIGHTNESS
2022-03-28
LAGGING OF EGB BOILER PIPE IN ER FOUND DETACHED
2024-04-03
FOUND DEFECTIVE PRESSURE GAUGE
2024-02-11
CORRECTIVE ACTIONS SHALL BE TAKEN FOR ALL SURFACES WITH TEMPERATURES ABOVE 220 °C
2022-02-23
DAMAGE RELEASE CONTROL CABINET IN CO2 ROOM-CASE 2
2022-02-18
IMPROPER USE OF TOOLS
2022-02-18
OIL COLLECTING BUCKETS AND OIL LEAKAGES AROUND G/ES AND M/E FUEL OIL PUMPS.
2024-02-11
CASCADE TANK INTERIOR
2024-02-11
DIRTY ENGINE ROOM MAY CAUSE A DETAINABLE DEFICIENCY
2023-09-10
EMERGENCY GENERATOR AIR VENTILATION STEEL CASING WAS FOUND CORRODED AND CRACKED.
2024-02-11
PORT SIDE SEWAGE DISCHARGE CONNECTION PIPE IN WRONG POSITION, ORIENTATION.
2024-02-11
BIG AMOUNT OF SLUDGE PRODUCTION
2022-02-13
FINGER CRUSHED BY SPANNER HANDLE
2022-02-13
DAMAGE RELEASE CONTROL CABINET IN CO2 ROOM
2022-02-18
A PURIFIER DAMAGE DURING START-UP OPERATION WITH ULSFO.
2022-01-12
RECORD OF ENGINE PARAMETER IN SHIP’S APPROVED NOX TECHNICAL FILE
2021-12-13
MSA CHINA´S ENQUIRY ABOUT SEWAGE AND STORAGE!
2024-02-11
AUXILIARY ENGINE, TURBOCHARGER´S INSULATION LAGGING
2021-10-29
A HOLE ON THE MAIN FIRE LINE IN VOID SPACE
2021-10-28
CARGO SPACES VENTILATION TRUNK SHOULD BE IN AN APPARENT SATISFACTORY CONDITION.
2021-10-25
ONE EXAMPLE OF “MAKING AMENDMENT TO THE ORB”
2021-10-24
AN UNSAFE CONDITION DUE TO A CORRODED HFO TRANSFER LINE /APPENDIX PIPE
2021-10-24
PSC EXPERIENCE IN CHINA (ARRANGEMENT OF VERTICAL LADDER INSIDE EMERGENCY ESCAPE TRUNK)
2024-02-11
DB WBT LEVEL SENSOR PIPING-GLAND CORROSION
2021-10-23
PSC EXPERIENCE IN AUS (AMSA) ELECTRICAL CIRCUIT (JUMPER)
2024-02-11
PSC EXPERIENCE IN AUS (AMSA)
2024-02-11
AN EXPERIENCE WITH INSULATION ON M/E EXHAUST GAS MANIFOLD
2021-10-22
DAMAGED GASKET ON INLET TO ME FUEL PUMP
2021-10-20
CHAIN BLOCK
2021-10-17
CHINA MSA ANTI POLLUTION ONLINE INSPECTION
2024-02-11
FIRE IN ENGINE SPACES OUR ISOLATION OF FUEL PIPES
2021-12-18
ONE USCG PSC FINDING REGARDING FUEL OIL SYSTEM
2024-02-11
ONE USCG PSC FINDING REGARDING MACHINERY AND MARINE PIPING SYSTEMS
2024-02-11
ONE USCG PSC FINDING REGARDING OILY BILGE WATER SYSTEM AT PHILADELPHIA
2024-02-11
MAIN ENGINE INSULATION
2021-10-16
A 50HZ FREQUENCY RATED MICROWAVE IN CREW MESSROOM
2021-10-16
SPRAY CAN IS NOT PERMITTED FOR THE INCINERATOR
2021-10-16
DAMAGED SELF RETRACTABLE LIFELINE
2021-10-16
IMPROPER NOT CALIBRATED TORQUE SPANNER WAS USED.
2021-10-16
PSC EXPERIENCE FROM A USCG
2024-02-11
PSC EXPERIENCE IN ASIA REGARDING ER OIL TANK GAUGES
2024-01-18
STEERING GEAR MOTOR CONTACTOR FAILURE
2021-10-16
STEERING GEAR PUMP TESTING CREW ENCOUNTERED A FAILURE OF SERVO PUMP
2021-10-16