loading...



Filter:
Category: X Paris MoU (118)
1 2 3 4 5 6 All
PSC FOCUS: 03104 - CARGO & OTHER HATCHWAYS_CARGO & OTHER HATCHWAYS- WEATHER DECK BALLAST TANK HATCHES FOUND WITH DOGGING ARRANGEMENTS NOT AS REQUIRED. SOME MISSING DOGS. OTHER DOGS WASTED TO THE POINT OF NO BITE UNDER TENSION AND READILY SLIPPING OFF. MUL
2026-06-04
PSC FOCUS: 18424 - STEAM PIPES, PRESSURE PIPES, WIRES (INSULATION)_STEAM PIPES, PRESSURE PIPES, WIRES (INSULATION)- PIPEWORK RELEASING HOT STEAM AT WALKWAY LEVEL FROM GATE VALVE IN ENGINE ROOM.
2026-06-04
PSC FOCUS: 10119 - RUDDER ANGLE INDICATOR_RUDDER ANGLE INDICATOR AT EMERGENCY STEERING POSITION DID NOT RELATE TO THE ACTUAL POSITION OF THE RUDDER. INDICATOR WAS ALSO NOT SECURE.
2026-06-04
PSC FOCUS: 18409 - DANGEROUS AREAS - SAFETY CHAINS ON THE WORKING PLATFORM OF STARBOARD SIDE HOSE HANDLING CRANE AND AFT DAVIT INEFFECTIVE TO PREVENT FALL FROM HEIGHT.
2026-05-30
PSC FOCUS: 07106- FIRE DETECTION AND ALARM SYSTEM_FIRE ALARM SYSTEM MANUAL CALL POINT AT BOSUN STORE ENTRANCE DETACHED FROM BULKHEAD AND SECURED WITH CABLE TIES.
2026-05-29
PSC FOCUS:07105-FIRE DOORS/OPENINGS IN FIRE-RESISTING DIVISIONS_THE SELF-CLOSING DEVICE ON THE FIRE DOOR ON THE AFT OF THE ACCOMMODATION BLOCK 'A'-DECK (ADJACENT TO MASTER'S CABIN) WAS CORRODED AND FULLY DETACHED FROM THE FRAME.
2026-05-29
PSC FOCUS: 03107-DOORS-EXTERNAL WEATHERTIGHT DOOR TO HOSPITAL FOUND WITH MECHANISM EXCESSIVELY STIFF AND DOGS NOT PROPERLY ENGAGING.
2026-05-29
PSC FOCUS: 031-DOORS-BOSUN'S STORE COAMING WASTED IN WAY OF DOGS ON WEATHERTIGHT DOOR. DAYLIGHT SHOWING THROUGH CLOSED DOOR.
2026-05-29
PSC FOCUS: 03103-RAILING, GANGWAY, WALKWAY AND MEANS FOR SAFE PASSAGE_WEATHER DECK GANGWAY SHELTER FORWARD STARBOARD SIDE FOUND STOWING ROPES AND UNABLE TO BE USED AS SHELTER.
2026-05-29
PSC FOCUS_LIFESAVING SIGNALS_LIFESAVING SIGNALS POSTER WAS NOT DISPLAYED ON THE NAVIGATION BRIDGE AS REQUIRED
2026-05-20
PSC FOCUS: VOYAGE OR PASSAGE PLAN
2026-05-20
PSC FOCUS: FIRE FIGHTING EQUIPMENT AND APPLIANCES_MULTIPLE FIRE HOSES WERE FOUND WITH DUCT TAPE APPLIED TO THE HOSE ENDS. AFTER REMOVAL OF THE TAPE DURING INSPECTION, TWO ENGINE ROOM FIRE HOSES WERE FOUND DEGRADED AND NOT FIT FOR USE.
2026-05-18
PSC FOCUS: MEANS OF ESCAPE_MEANS OF ESCAPE FROM STEERING GEAR ROOM WAS NOT POSSIBLE TO OPEN FROM INSIDE. ARRANGEMENT MUST BE MODIFIED TO MAKE IT POSSIBLE TO OPEN FROM INSIDE EVEN IF IT IS LOCKED WITH A PADLOCK ON THE OUTSIDE. UNTIL RECTIFIED, THE DOOR SHA
2026-05-07
PSC FOCUS: PREVENTION OF OCCUPATIONAL INJURIES AND DISEASES_HEAVY BOXES, SPARE PARTS, AND MATERIALS WERE FOUND IMPROPERLY SECURED OR UNSECURED IN WEATHER PASSAGES AND THE STEERING GEAR ROOM.
2026-04-20
PSC FOCUS: CREW TRAINING AND FAMILIARIZATION_JUNIOR OFFICERS DEMONSTRATED INSUFFICIENT KNOWLEDGE OF THE BALLAST WATER MANAGEMENT PLAN (BWMP).
2026-04-20
PSC FOCUS: GAUGES AND THERMOMETERS_ONE THERMOMETER ON AIR COMPRESSOR NO.1 AND ONE PRESSURE GAUGE ON AIR COMPRESSOR NO.2 WERE FOUND BROKEN OR NOT OPERATIONAL.
2026-04-19
PSC FOCUS: AUXILIARY ENGINE SYSTEMS_AUXILIARY ENGINES NO.1, NO.2, AND NO.4 HAVE ACTIVE OIL LEAKAGES OBSERVED DURING INSPECTION.
2026-04-17
PSC FOCUS: SAFETY SIGNS AND INDICATIONS_IMO-TYPE EXIT, ESCAPE, AND SAFETY SIGNS WERE FOUND TO BE FADED, PAINTED OVER, MISSING, OR NOT OF THE CORRECT TYPE IN THE ENGINE ROOM, STEERING GEAR ROOM, AND ACCOMMODATION AREAS.
2026-04-17
PSC FOCUS: VOYAGE DATA RECORDER (VDR / S-VDR)_THE VOYAGE DATA RECORDER (VDR) WAS FOUND INOPERATIVE. ALTHOUGH A FLAG STATE DISPENSATION LETTER WAS AVAILABLE ON BOARD, THE MASTER FAILED TO INFORM THE PORT STATE AUTHORITY PRIOR TO ARRIVAL AS REQUIRED. SERVIC
2026-04-01
PSC FOCUS: PERSONAL PROTECTIVE EQUIPMENT (PPE)_DURING LOWERING OF A LIFEBOAT, A CREW MEMBER OPERATED WITHOUT SAFETY GLOVES WHILE HANDLING MOVING MECHANICAL PARTS (WIRES UNDER TENSION). THE MASTER INSTRUCTED A SAFETY MEETING WITH ALL CREW BEFORE DEPARTURE.
2026-03-29
PSC FOCUS: REMOTE MEANS OF CONTROL (OPNENING, PUMPS, VENTILATON, ETC) MACHINERY SPACES_DURING TESTING, LOCAL QUICK-CLOSING VALVES OF DG NO.1 AND DG NO.3 SHOWED HYDRAULIC LEAKAGES.
2026-03-28
PSC FOCUS: CODE 02150_STEERING GEAR_HYDRAULIC PIPELINE CONNECTION SHOWS SEVERAL POINT OF SMALL LEAKAGES. THE SYSTEM IS FULLY OPERATIVE.
2026-03-27
PSC FOCUS: BEAMS, FRAMES, FLOORS-CORROSION_HATCH COVER BEAMS ARE HEAVILY RUSTED AND CORRODED IN SOME POINTS
2026-03-27
PSC FOCUS: PERMANENT MEANS OF ACCESS_THE GANGWAY DOESN’T TOUCH THE GROUND, AND ANOTHER SMALLER GANGWAY HAS BEEN SECURED TO THE MAIN ONE TO LET PEOPLE REACH THE VESSEL
2026-03-26
PSC FOCUS: EMERGENCY SOURCE OF POWER - EMERGENCY GENERATOR_DURING THE BLACKOUT TEST, AFTER HALF AN HOUR OF OPERATION, THE HIGH-TEMPERATURE COOLING ALARM OF THE EMERGENCY GENERATOR SOUNDED, WITH LEAKAGE ON THE COOLING CIRCUIT.
2026-04-29
PSC FOCUS: CLEANLINESS_ OIL LEAKAGE OBSERVED INTO CEILING IN CREW DAYROOM, CAUSED BY A LEAKING PIPE TO MOORING WINCH ON DECK ABOVE.
2026-03-27
PSC FOCUS: ON BOARD TRAINING AND INSTRUCTIONS
2026-03-27
PSC FOCUS: RESCUE BOATS
2026-03-27
PSC FOCUS: ONBOARD PROGRAMME FOR THE PREVENTION OF OCCUPATIONAL INJURIES AND DEASEASES
2026-03-27
PSC FOCUS: REMOTE MEANS OF CONTROL (OPNENING, PUMPS, VENTILATON, ETC) MACHINERY SPACES
2026-03-27
PSC FOCUS: LIFEBUOYS INCL. PROVISION AND DISPOSITON
2026-03-27
PSC FOCUS: FIXED FIRE EXTINGUISHING INSTALLATION
2026-03-27
PSC FOCUS: FIRE DOORS/OPENINGS IN THE FIRE-RESISTING DIVISION
2026-03-27
PSC FOCUS: ELECTRICIAL INSTALLATIONS IN GENERAL
2026-03-27
PSC FOCUS: FIRE DETECTION AND ALARM SYSTEM
2026-03-27
PSC FOCUS: DANGEROUS AREAS
2026-03-27
PSC FOCUS: LAUNCHING ARRANGEMENTS FOR RESCUE BOAT
2026-03-27
PSC FOCUS: CLEANLINESS
2026-03-27
PSC FOCUS: HEATING, AIR CONDITIONING AND VENTILATION
2026-03-27
PSC FOCUS: NOISE, VIBRAATION AND OTHER AMBIENT FACTORS
2026-03-27
PSC FOCUS: SANITARY FACILITIES_FLUSHING SYSTEM AND OPEN/CLOSE DEVICE REGARDING VENTILATION INSIDE SOME CABINS FOUND INOPERATIVE
2026-01-26
PSC FOCUS: TOWING AND MOORING EQUIPMENT_SOME MOORING DEVICES LOCATED IN POOP DECK AND FORWARD FOUND IN POOR MAINTENANCE CONDITION (BLOCKED)
2026-01-26
PSC FOCUS: OTHER (ACCOMODATION, RECREATIONAL FACILITIES)_MATTRESSES FOUND WITHOUT FIREPROOF EVIDENCE
2026-01-26
PSC FOCUS: GALLEY HANDLINGROOM (MAINTENANCE)_KITCHEN HOOD (EXTRACTOR SYSTEM) FOUND DIRTY AND IN POOR CONDITION
2026-01-26
PSC FOCUS: EMERGENCY, LIGHTING, BATTERIES AND SWITCHES_FOUND SOME EMERGENCY LIGHTS (CLOSE TO THE HOSPITAL DOOR AND FREE FALL) INOPERATIVE
2026-01-26
PSC FOCUS: SOLAS STATUTORY DRILLS – INSUFFICIENT FREQUENCY_MORE THAN 25% OF CREW MEMBERS WERE CHANGED, HOWEVER FIRE DRILL AND ABANDON SHIP DRILL NOT PERFORMED WITHIN 24H OF THE SHIP LEAVING THE PORT.
2026-01-24
PSC FOCUS: GALLEY EQUIPMENT_THE CONVECTION OVEN + STEAMER INSIDE GALLEY IS BROKEN DOWN LONG TIME ALREADY. COMPANY NEEDS TO SUPPLY VESSEL WITH REPLACEMENT COMBINED CONVECTION OVEN + STEAMER.
2025-11-18
PSC FOCUS: BOILER ROOM VENTILATION DUCT
2025-11-15
PSC FOCUS ON SEAFARERS' EMPLOYMENT AGREEMENT (SEA)_THE SEA OF TWO PERSONS ON BOARD, MENTIONS THEIR CAPACITY ON BOARD AS BEING CADET...
2025-11-03
PSC FOCUS ON VOYAGE OR PASSAGE PLAN_IN THE LAST VOYAGE IT WAS NOTICED THAT REQUIRED NAVTEX STATIONS ARE NOT FILLED IN ON THE VOYAGE PLAN AND FROM WAYPOINT....
2025-10-28
PSC FOCUS ON MONITORING OF VOYAGE OR PASSAGE PLAN_NO EVIDENCE FOUND OF ANY POSITION FIXING CARRIED OUT DURING LAST VOYAGE AS REQUIRED BY SIGNED PASSAGE PLAN. THE USE OF ECDIS SAFETY SETTING COULD NOT BE EXPLAINED.
2025-10-28
PSC FOCUS ON FIRE DOORS/OPENINGS IN FIRE-RESISTING DIVISIONS_AMONGST TO OTHER FINDINGS, IT WAS NOTICED THAT THE SELF CLOSING MECHANISMS....
2025-10-26
PSC FOCUS ON BALLAST WATER MANAGEMENT PLAN_NO APPROVAL, NO RECORD., NO CRY....
2025-10-25
PSC FOCUS ON CLEANLINESS_SIGNS OF INSECT INFESTATION WERE FOUND WITHIN THE GALLEY
2025-10-07
PSC FOCUS ONBOARD PROGRAMME FOR THE PREVENTION OF OCCUPATIONAL INJURIES AND DEASEASES_THE BOARDING AREA TO THE FREE FALL LIFEBOAT HAS AN OPEN RAIL.....
2025-10-06
PSC FOCUS ON COW OPERATIONS AND EQUIPMENT MANUAL_COW MANUAL LISTS TANKS 3(C) & 4(C) AS HEAVY BALLAST, BUT ONLY 3(C) WAS WASHED REGULARLY...
2025-10-03
PSC FOCUS ON LOGBOOKS COMPULSORY ENTRIES_IN BOTH THE OFFICIAL LOGBOOK AND DECK LOGBOOK, THE LAST DRAUGHT ENTRIES WERE RECORDED AT DEPARTURE FROM THE PREVIOUS PORT, BUT NO ENTRIES WERE MADE FOR THE NEXT PORT (ARRIVAL/DEPARTURE, E.G., WILHELMSHAVEN). MISSIN
2025-10-02
PSC FOCUS ON FIRE DOORS/OPENINGS IN FIRE-RESISTING DIVISIONS_EMERGENCY EXIT IN ENGINE ROOM AT LOWEST PLATFORM AFT IS NOT CLOSING BY ITSELF/PROPERLY
2025-10-01
PSC FOCUS ON LOGBOOKS COMPULSORY ENTRIES_CARGO TANK VENT SYSTEM- NO EVIDENCE OF FUNCTION OF P/V VALVES ON DECK
2025-09-30
PSC FOCUS ON STABILITY/ STRENGTH/LOADING INFORMATION AND INSTRUMENT_FOUND DISCREPANCIES...
2025-09-26
PSC FOCUS ON SEA & CBA COMPLIANCE [SEAFARERS' EMPLOYMENT AGREEMENT (SEA) (CONTRACT) AND THE COLLECTIVE BARGAINING AGREEMENT (CBA)]
2025-09-25
PSC FOCUS FOR CONTINUES SYNOPSIS RECORD (CSR) & AMENDMENT AND INDEX FORMS_CSR NO.3 ON BOARD LISTED OWNER UNDER SAME FLAG, BUT INSURANCE CERTIFICATES SHOWED DIFFERENT OWNER. VESSEL LATER PRESENTED CSR NO.4 (12/2023) WITH NEW OWNER IN CHINA, THOUGH REGISTER
2025-09-23
PSC FOCUS FOR SHIP'S OCCUPATIONAL SAFETY AND HEALTH POLICIES AND PROGRAMMES_WHEN LOCKERS OVERFLOW AND CYLINDERS ROLL, PSC ROLLS OUT A DEFICIENCY!
2025-09-09
PSC FOCUS FOR UMS SHIP_AUTOMATIC PRINTING = AUTOMATIC COMPLIANCE, LET THE PRINTER WORK FOR YOU
2025-09-08
PSC FOCUS FOR GUARDS - FENCING AROUND DANGEROUS MACHINERY PARTS_MISSING EQUIPMENT
2025-09-05
PSC FOCUS FOR COLD ROOM CLEANLINESS & TEMPERATURE_BUT IT IS JUST A SMALL LIGHT!
2025-09-04
PSC FOCUS FOR OPERATION OF MACHINERY_LACK OF FAMILIRIZATION
2025-09-03
PSC FOCUS FOR GAUGES, THERMOMETERS, ETC_GAUGE RAGE – PSC’S FAVORITE CATCH!
2025-09-02
PSC FOCUS FOR PROPULSION MAIN ENGINE_COOLING WATER LEAKS UNDER PSC SPOTLIGHT
2025-09-01
PSC FOCUS FOR INFLATABLE LIFERAFTS_NOT PROPERLY MARKED_LIFERAFTS SHOULDN’T BE A MYSTERY BOX!
2025-08-31
PSC FOCUS FOR LIFEBOATS_NOT READY FOR USE...
2025-08-30
PSC FOCUS FOR FIRE FIGHTING EQUIPMENT AND APPLIANCES_YOUR FIRST LINE OF DEFENSE IS ONLY AS STRONG AS ITS READINESS.
2025-08-29
PSC FOCUS FOR FIRE DETECTION_SMOKE DETECTION IS YOUR FIRST LINE OF DEFENSE AGAINST FIRE
2025-08-28
PSC FOCUS FOR MEANS OF COMMUNICATION BETWEEN SAFETY CENTRE AND OTHER CONTROL STATIONS_“HELLO? …HELLO? …PSC IS CALLING!”
2025-08-27
PSC FOCUS FOR COVERS (HATCHWAY-, PORTABLE-, TARPAULINS, ETC.)_WATERTIGHT INTEGRITY COMPROMISED
2025-08-26
PSC FOCUS FOR COVERS (HATCHWAY-, PORTABLE-, TARPAULINS, ETC.)_HATCH & DUCT KEEL CONDITION!
2025-08-25
PSC FOCUS FOR CARGO AND OTHER HATCHWAYS_SEVERE CORROSION, WASTED BRACKETS, AND DETACHED GASKET CHANNELS = DETENTION AT QUéBEC
2026-05-06
PSC FOCUS FOR A-TYPE PORTABLE GANGWAY_DON’T GET CAUGHT ON THE WRONG ANGLE
2025-08-21
PSC FOCUS FOR ORB ENTRANCE_ ALWAYS RECORD BUNKERING OPERATIONS IN ORB PART I WITHOUT DELAY TO AVOID PSC DEFICIENCIES
2025-08-20
PSC FOCUS FOR SEA & CBA COMPLIANCE_SEAFARERS' EMPLOYMENT AGREEMENT (SEA) (CONTRACT) AND THE COLLECTIVE BARGAINING AGREEMENT (CBA)
2025-08-19
PSC FOCUS FOR MLC_DMLC PART I & PART II_DMLC DOCUMENTS – ALWAYS ON BOARD, ALWAYS UPDATED
2025-08-18
PSC FOCUS BALLAST WATER RECORD BOOK (BWRB)
2025-03-25
PSC OBSERVATION: EMERGENCY SYSTEMS
2024-11-13
PSC OBSERVATION: FLOOR PLATES IN ENGINE ROOM
2024-11-08
PSC OBSERVATION: INADEQUATE CONDITION OF OPERATING MUSHROOM VENTILATOR
2024-11-08
PSC OBSERVATION: BALLAST WATER TREATMENT SYSTEM
2024-11-07
PSC OBSERVATION: UNSAFE CONDITION - CLOGGING OF AIRCON DRAINAGE PIPE
2024-11-06
PSC OBSERVATION: ARE YOUR FIRE DOORS MAINTAINED IN GOOD WORKING CONDITION?
2024-11-07
PSC OBSERVATION: UNAPPROVED SMPEP / SOPEP PLANS
2024-11-03
PSC OBSERVATION: CERTIFICATE OF RECOGNATION
2024-11-02
PSC OBSERVATION: MISSING TECHNICAL FILE
2024-10-30
PSC OBSERVATION: WORK AND REST HOUR
2024-10-30
PSC OBSERVATION: BWM PLAN APPROVAL!
2024-10-27
PSC FOCUS FOR SWL MARKING
2024-09-03
PSC FOCUS FOR SAFETY - LATHE MACHINE
2024-09-03
PSC FOCUS FOR FIRE / SPARK PROOF SAFETY CURTAIN
2024-09-02
PSC FOCUS FOR THE BOTTOM PLATFORM GRATINGS IN THE ENGINE ROOM
2024-09-02
PSC FOCUS FOR EMERGENCY SOURCE OF POWER – EMERGENCY GENERATOR
2024-05-25
PSC FOCUS FOR AUXILIARY ENGINE
2024-04-26
PSC FOCUS FOR PROPULSION MAIN ENGINE
2024-04-26
PSC FOCUS FOR INTERNATIONAL SEWAGE POLLUTION PREVENTIVE CERTIFICATE
2024-04-01
PSC FOCUS FOR HEALTH PROTECTION, MEDICAL CARE…
2024-04-01
PSC FOCUS FOR VENTILATORS, AIR PIPES, CASINGS
2024-04-01
PSC FOCUS FOR GAUGES, THERMOMETERS, ETC.
2024-03-29
PSC FOCUS FOR INTERNATIONAL AIR POLLUTION CERTIFICATE
2024-03-29
PSC FOCUS FOR SEAFARERS´ EMPLOYMENT AGREEMENT (SEA) - MLC 2006 TITLE 2 / STANDARD 2.1
2024-03-29
PSC FOCUS FOR HOUSKEEPING IN THE CREW MESSROOM (MLC 2006 TITLE 3 / THE REGULATIONS AND THE CODE / STANDARD A3.2)
2024-03-29
FOCUS FOR PSC – POLUTION PREVENTION – MARPOL ANNEX IV – SEWAGE TREATMENT PLANT
2024-01-22
FOCUS FOR PSC – TEST CERTIFICATE ON BOARD FOR THE WIRE SLINGS FOR FFLB
2024-01-22
FOCUS FOR PSC – FIRE FIGHTING EQUIPMENT AND APPLIANCE – FIRE HOSE BOX
2024-01-22
THE HYDRAULIC INLET PIPE STAND FOR THE MOORING WINCH
2024-01-24
FINDING: HAWSE PIPES AT BOSUN STORE FOUND WITH LEAKS
2024-01-29
PSC DEFICIENCY FOR FIRE-FIGHTER´S OUTFITS ABOUT THE MINIMUM ENGINEERING SPECIFICATIONS AS PER FSS CODE, WHICH REQUIRE THE OUTER SURFACE TO BE WATER RESISTANT.
2024-01-29
DEF#: THE PRINT-OUT OF THE NAVTEX IS NOT READABLE.
2024-02-05
PSC DEFICIENCY FOR SEVERAL CAPSTANS AND ROLLERS OVER WHICH MOORING ROPES ARE GUIDED ARE SEIZED
2023-09-12
FIRE-FIGHTER´S OUTFITS
2024-02-11
PSC EXPERIENCE IN EU (PILOT LADDER)
2024-02-11
LIFEBOAT WINDOWS NO LONGER CLEAR
2023-09-10