NUMERALS OF CARGO HOLDS HATCH COVER NATURAL VENTS LOUVRES AND FIRE SCREENS ARE FOUND CORRODED!
hatch cover natural vents louvreslouvre
2023-09-12
FIREMAN OUTFIT´S TWO-WAY PORTABLE RADIOTELEPHONE APPARATUS (VHF) WERE FOUND INOPERATIVE / FULLY DISCHARGED.
two-way portable radiotelephonefireman outfitSOLAS II-2, Reg. 10.10.4
2024-01-29
REMOVABLE GRATING FELL AND HIT ONE CREW MEMBER ON HIS HEAD AND CAUSED A CUT ON HIS LEFT EYE BROWSE
PSC DEFICIENCY FOR FIRE-FIGHTER´S OUTFITS ABOUT THE MINIMUM ENGINEERING SPECIFICATIONS AS PER FSS CODE, WHICH REQUIRE THE OUTER SURFACE TO BE WATER RESISTANT.
FSS Codefire-fighter´s outfitswater resistant
2024-01-29
ECDIS - SAFETY CONTOUR AND SAFETY DEPTH FUNCTION
Shallow contourSafety contourSafety depthDeep contourENC
2022-10-28
BREATHING APPARATUS SET AND SPARE CYLINDERS
fire drillintrinsically safefireman outfitfire-fighter´s outfitSpare cylindersBreathing Apparatus Set
2022-10-25
ANTI SPLASH TAPE IS MISSING ON THE AREA OF INLET - OUTLET OF FUEL OIL´S FANGE FOR ME FUEL HIGH PRESSURE PUMP!
anti splash tape
2022-10-25
FIRE LINE CORRODED IN FRONT ACCOMMODATION. TO BE REPAIRED AND TESTED!
IMPROPER MAINTAINED VERTICAL AND HORIZONTAL ROLLER FAIR LEAD, CAPSTAN AND GUIDE ROLLER
Horizontal roller fair leadGuide rollerVertical roller fair lead
2022-10-22
ER PIPING SHOULD BE FREE OF ANY CEMENT BOXES, DOUBLERS, SOFT PATCHES, ETC
doublerssoft patchescement boxesER piping
2023-09-12
PSC DEFICIENCY: MOB SIGNAL LANYARDS IS SHORTER THAN REQUIRED
MOB SignallanyardLSA Code
2024-02-02
BOARDING / ACCESS ACCOMMODATION LADDER
Accommodation laddersafety netbuoy
2022-10-05
PSC DEFICIENCY: THERE IS A BEND AND ALSO OBSERVED CRACKS ON SOME STEPS ON AN ACCOMMODATION LADDER.
Accommodation ladder
2023-09-12
THE CHEMICAL PROTECTIVE SUITS ARE A STATUTORY REQUIREMENT COMING FROM SOLAS CH.II-2
MED mark of conformitywheelmarkchemical suitsChemical Protective SuitsSOLAS Ch.II-2
2024-02-02
PSC DEF: MAX NUMBER OF PERSONS AND MAXIMUM AND MINIMUM ANGLE MUST BE MARKED ON TOP AND BOTTOM PLATFORMS OF GANGWAY
max number of personsminimum angleIMO MSC.1/Circ.1331/3.5
2023-09-12
PSC DEF ABOUT A LIFEBOAT LASHING EYE WHICH WAS FOUND AS HEAVILY WORN OUT!
lifeboatlifeboat lashing eyeMSC.402(96)
2023-09-12
A SMALL NOTE FOR FIRE-FIGHTER'S ELECTRIC SAFETY LAMP!
fire-fighter's electric safety lamp
2022-09-26
FOUND DAMAGED CHEMICAL OUTFITS ON BOARD.
wheelmarkChemical Protective Suitschemical outfitsSOLAS Ch.II-2.MED mark
2022-09-14
WHEELHOUSE FIXED RECTANGULAR WINDOW GLASS FOUND CRACKED TO BE REPAIRED
A 2.3.1 SOLAS regulation 19 and 22bridge windowwheelhousewindow glassplexiglass
2024-02-02
PSC DEFICIENCY / EXCESSIVELY THICK GREY / BLACK SMOKE FROM THE SHIP´S FUNNEL.
thick greyblack smokefunnel
2024-02-02